accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. 4715 (RP-1042) - Double-Walled Heat Exchanger Risk Analysis for Group B1 and Group B2 Refrigerants

4715 (RP-1042) - Double-Walled Heat Exchanger Risk Analysis for Group B1 and Group B2 Refrigerants ✓ Most Recent

1718025

Conference Proceeding by ASHRAE , 2004

Aaron E. Berger; Donald L. Fenton, Ph.D., P.E.; Prasad V. Kaitay; Shuting Lei, Ph.D.

Track This

Full Description

In compliance with ANSI/ASHRAE Standard 15-2001, Safety Standard for Refrigeration Systems, a large quantity of Group B1 or Group B2 refrigerant cannot enter the occupied space of a building. Instead, a secondary fluid must be used to circulate through the refrigeration system’s components located within the occupied space. In typical systems, a single-walled liquid-to-liquid heat exchanger is used outdoors with an air coil in the occupied space. In this study, a double-walled heat exchanger is considered to replace these two components, where the double-walled configuration prevents leaking refrigerant from entering the occupied space of a building. Consequently, the double-walled heat exchanger located in the occupied space serves as a direct expansion coil. While any Group B1 or Group B2 refrigerant may be considered, ammonia, which is a Group B2 refrigerant, became the focus of this study due to the availability of commercial absorption units.

Four refrigeration system concepts are developed. One system—the reference system—represents current system design, incorporating a single-walled heat exchanger and an air coil. Three other proposed systems are also described, each containing a double-walled heat exchanger. Twelve design criteria accompany these proposed systems, which must meet the safety requirements provided.

From reliability data gathered and the calculations made, the three proposed conceptual systems are found to be at least as, if not more, reliable than the reference conceptual system in two comparisons. Considering the systems in their entirety, the reference system has a reliability value of 0.639, and the three proposed conceptual systems have reliability values of 0.654 or greater. Similar results in comparison are attained when considering the portion of the system from which refrigerant would escape to the occupied space.

Since the proposed system reliabilities are equivalent to the reference system using a secondary fluid, the proposed systems are determined to be no more of a risk to safety than current systems. Thus, the application of the double-walled heat exchanger, which permits the refrigerant to enter the occupied space, appears acceptable on the basis of this risk analysis.

Units: SI

See more

Also Bought By Customers

  • 1712223

    4738 (RP-1146) - Proposed Tools and Capabilities for Proa...
    Priced From $16.00

  • 1715663

    4701 – A Comparison of Electrical- and Thermal-Load-Follo...
    Priced From $16.00

  • 1718010

    4698 – Application of Advanced Software Technologies and ...
    Priced From $16.00

  • 1718011

    4699 (RP-1121) – Dehumidification Characteristics of Comm...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2004 Annual Conference, Nashville, TN > Transactions 2004, Vol 110, pt. 2 > Technical Papers
  • ASHRAE > Transactions > Transactions 2004, Vol. 110, pt. 2 > Technical Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2004

Number of Pages:

14

File Size:

1 file

Product Code(s):

D-23214

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/4715-rp-1042-double-walled-heat-exchanger-risk-analysis-for-group-b1-and-group-b2-refrigerants?product_id=1718025
Referrer: Direct Navigation
IP: 216.73.216.61
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463809869
Order #: None
Cookies: YES
×