accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. ASSE (Plumbing) 1019-2004

ASSE (Plumbing) 1019-2004 Historical

1219046  Preview

Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining Type

standard by American Society of Sanitary Engineering , 02/01/2004

This document has been replaced. View the most recent version.
Track This
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

The purpose of these devices is to supply potable water without danger of damage to the device due to freezing; and to provide protection of the potable water supply from contamination due to back siphonage or back pressure less than or equal to 3 meters (10 feet) of head pressure. This standard covers design and performance requirements for water supply system wall hydrant devices. These devices shall have a permanent means including air inlet valve(s) to prevent backflow from a potential health hazard due to back siphonage, and back pressure less than 3 meters (10 feet) of head pressure. The device shall only be used on systems where the only source of back pressure comes from an elevated hose equal to or less than 3 meters (10 feet) in height and from full rated supply pressure. The devices shall be classified as follows: (a) Type A: These hydrants automatically drain the water when the water supply is shut off and the hose removed to prevent damage from freezing; (b) Type B: These hydrants automatically drain the water with a hose removed or attached, end nozzle closed, and the hydrant valve closed; and (c) Type C: Same as Type A. Backflow prevention is achieved by alternate principle of holding pressure versus relieving pressure. See more

Also Bought By Customers

  • 14958

    ASME A112.19.1M-1994 (R2004)
    Enameled Cast Iron Plumbing Fixtures
    Priced From $65.00

    ASME A112.19.1M-1994 (R2004): Enameled Cast Iron Plumbing Fixtures

  • 2568291

    ASSE (Plumbing) 1003-23/CSA B356:23
    Water pressure reducing valves for potable water distribution systems
    Priced From $45.00

    ASSE (Plumbing) 1003-23/CSA B356:23: Water pressure reducing valves for potable water distribution systems

  • 2923440

    ASSE (Plumbing) /IAPMO/ANSI/CAN 1079-2024
    Performance Requirements for Dielectric Pipe Unions
    Priced From $45.00

    ASSE (Plumbing) /IAPMO/ANSI/CAN 1079-2024: Performance Requirements for Dielectric Pipe Unions

  • 2922437

    ASME A112.19.2-2024/CSA B45.1:24
    Ceramic Plumbing Fixtures
    Priced From $130.00

    ASME A112.19.2-2024/CSA B45.1:24: Ceramic Plumbing Fixtures

 

Document History

  1. ASSE (Plumbing) 1019-2023

    November 2023
    Performance Requirements for Wall Hydrant with Backflow Protection and Freeze Resistance

    • Most Recent  Most Recent
  2. ASSE (Plumbing) 1019-2011 (R2016)

    September 2011
    Performance Requirements for Wall Hydrant with Backflow Protection and Freeze Resistance

    • Historical Version
  3. ASSE (Plumbing) 1019-2004

    You are currently viewing this product 👀 currently
    viewing

    February 2004
    Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining Type

    • Historical Version

Order Options

Delivery Options
Price: $45.00
Available for Immediate Download

Product Details

Published:

02/01/2004

Number of Pages:

24

File Size:

1 file , 130 KB

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/asse-plumbing-1019-2004?product_id=1219046
Referrer: Direct Navigation
IP: 216.73.217.154
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463906901
Order #: None
Cookies: YES
×