accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. AT-01-10-2 -- Effect of Tilt Angle and Temperature Difference on Solar Heat Gain Coefficient Measurement of Fenestration System

AT-01-10-2 -- Effect of Tilt Angle and Temperature Difference on Solar Heat Gain Coefficient Measurement of Fenestration System ✓ Most Recent

1719428

Conference Proceeding by ASHRAE , 2001

Ching-Chia (Thomas), Tseng D. Yogi Goswami, Ph.D., P.E.

Track This
👥 Multi-User PDF
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

The solar heat gain coefficient (SHGC) of a fenestration system can be determined experimentally by two methods. One method determines the SHGC by summing the transmittance and a portion of the absorptance of a fenestration system and the other measures the SHGC by solar calorimetry. In this research, the SHGC of a fenestration system consisting of a glass window and a black shade was determined by using both the test methods at solar incidence angles from 20° to 30°, panel tilt angles of 45°and 90°, and various air temperature differences between the calorimeter chamber and the ambient. From the solar optical properties measured using the black box method, the SHGC of the glass/aluminum shade combined fenestration system was estimated to be between 0.75 and 0.83, with 0.79 being the average value for incident angles between 20° and 30°. Using the UF/ASHRAE solar calorimeter, SHGC for a 45° panel tilt was measured to be 0.80, 0.76, and 0.60, respectively, for small, medium, and large air temperature differences. SHGC for a 90° panel tilt was measured as 0.83, 0.74, and 0.59, respectively, for small, medium, and large air temperature differences. These results show that the air temperature differ-ence between solar calorimeter chamber and the ambient is the major factor that affects the SHGC measurement. Experiments from six groups for different combinations of the air temper-ature difference and panel tilt angles produced a standard deviation of only 2.8%. The results show that the effect of panel tilt angle from 45° to vertical is not significant.

Units: SI

See more

Also Bought By Customers

Also Bought By Customers…

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2001 Winter Conference, Atlanta, GA > Transactions 2001, Vol. 107, pt. 1 > Symposium Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2001

Number of Pages:

7

File Size:

1 file , 230 KB

Product Code(s):

D-7175

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/at-01-10-2-effect-of-tilt-angle-and-temperature-difference-on-solar-heat-gain-coefficient-measurement-of-fenestration-system?product_id=1719428
Referrer: Direct Navigation
IP: 216.73.216.209
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463994379
Order #: None
Cookies: YES
×