accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. AWWA C508-09

AWWA C508-09 Historical

1662326

Swing-Check Valves for Waterworks Service, 2 In. (50 mm) Through 24 In.( 600 mm) NPS

standard by American Water Works Association , 01/01/2010

This document has been replaced. View the most recent version.

📝 Amendments Available

Track This

Full Description

This standard covers only iron-body, bronze-mounted, nonassisted, swing-check valves, 2-24 in. (50-600 mm) NPS, with mechanical-joint or flanged ends that are installed horizontally in water systems. The manufacturer should be consulted for special conditions. Check valve sizes covered by this standard are 2, 2 1/2, 3, 4, 6, 8, 10, 12, 16, 20 and 24 in. (50, 65, 75, 100, 150, 200, 250, 300, 400, 500 and 600 mm) NPS. Sizes refer to the nominal diameter of the waterway through the inlet and outlet connections and the seat ring. 1.1.1 Seating types. Check valves may be of the metal-to-metal seat construction or resilient material-to-metal seat construction. Check-valve body ends shall be flanged or mechanical joint. 1.1.2 Waterway types. Swing-check valves may be of the clear waterway design (where the disc in the full open position swings clear of the waterway) or the full waterway design (where the disc in the full open position is not clear of the waterway but the body is enlarged to provide full waterway area around the disc). In either design, when fully open, the new flow area shall not be less than the area of a circle with a diameter equal to the nominal pipe size. 1.1.3 Pressure ratings. The working water pressure shall be 175 psig (1200 kPa) for check valves with diameters of 2-12 in. (50-300 mm) NPS inclusive. The working water pressure shall be 150 psig (1030 kPa) for check valves 16-24 in. (400-600 mm) NPS inclusive. The working water temperature shall not exceed 125F (52C). 1.1.4 Conditions not covered. The following design and installation conditions are not covered by this standard. 1.1.4.1 Swing-check valves for use in lines conveying water of unusual corrosivity are not covered by this standard. 1.1.4.2 Conditions of water hammer, hydraulic pulsation, and excessive operating noise are beyond the scope of this standard and require special design and construction consideration. See more

Also Bought By Customers

  • 2208901

    AWWA C515-20
    Priced From $140.00

  • 2073737

    AWWA C500-19
    Priced From $140.00

  • 3009475

    ASME B16.5-2025
    Priced From $360.00

  • 3009142

    ASME B16.34-2025
    Priced From $300.00

 

Document History

  1. AWWA C508-25

    July 2025
    Swing-Check Valves for Waterworks Service, 2-In. Through 48-In. (50-mm Through 1,200-mm) NPS

    • Most Recent  Most Recent
  2. AWWA C508-17

    June 2017
    Swing-Check Valves for Waterworks Service, 2-In. Through 48-In. (50-mm Through 1200-mm) NPS

    • Historical Version
  3. AWWA C508-09

    You are currently viewing this product 👀 currently
    viewing

    January 2010
    Swing-Check Valves for Waterworks Service, 2 In. (50 mm) Through 24 In.( 600 mm) NPS

    • Historical Version
  4. AWWA C508-01

    September 2001
    Swing-Check Valves for Waterworks Service, 2 In. (50 mm) Through 24 In.( 600 mm) NPS

    • Historical Version
  5. AWWA C508-93

    January 1993
    Swing-Check Valves for Waterworks Service, 2 in. (50mm) Through 24 in. (600mm) NPS (includes addendum C508a-93)

    • Historical Version
 

Amendments, rulings, supplements, and errata

  1. AWWA C508-09a-11

    Free
    Download

    April 2012
    Addenda to ANSI/AWWA C508-09: Standard for Swing-Check Valves for Waterworks Service, 2 In. (50 mm) Through 24 In.( 600 mm) NPS

Browse related products from American Water Works Association

  • American Water Works Association > Standards > Valves and Hydrants

Order Options

Delivery Options
Price: $140.00
Available for Immediate Download

Product Details

Published:

01/01/2010

ANSI:

ANSI Approved

Number of Pages:

30

File Size:

1 file

Note:

This product is restricted and cannot be purchased in the following countries Ukraine, Russia, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
Printed Edition + PDF
A combination of a Hard Copy product that is mailed and an electronic product such as a PDF or SPDF (Secure PDF). Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/awwa-c508-09?product_id=1662326
Referrer: Direct Navigation
IP: 216.73.216.4
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463689818
Order #: None
Cookies: YES
×