accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. BIM-integrated Indoor Aerosol Modeling Based On Outdoor Particles In Germany

BIM-integrated Indoor Aerosol Modeling Based On Outdoor Particles In Germany ✓ Most Recent

2242203

Conference Proceeding by ASHRAE , 2021

Jan Drzymalla, MEng;Jannick Höper, MEng;Sven Eckers, MEng

Track This

Full Description

Indoor air quality (IAQ) plays an intrinsic role in occupant comfort, and should be evaluated as a key building performance indicator of early design phases. However, IAQ is very complex due to a plethora of chemical compounds in the indoor air and also depends on the activities in the building. Therefore, IAQ assessment is often not comprehensively considered, or applied only during late project phases. This study reviewed how Building Information Modeling (BIM) could be applied for IAQ performance analysis, to provide a more holistic design process. Accordingly, the integrability of Indoor Aerosol Modeling (IAM) into the open BIM data format Industry Foundation Classes was analyzed. The goal was to enable automated BIM-integrated IAM based on particle concentrations in Germany’s outdoor air. For this IAM, a Material Balance Model was chosen which is based on the principle of mass conversation and applies to a single zone. The analysis showed that eight Exchange Requirements (ERs), two Property Sets (Psets) and two Quantity Sets (Qsets) are required for the presented BIM-integrated IAM of naturally ventilated single-zone buildings, which form the basis for an Information Delivery Manual, a Model View Definition and a BIM application case. One of the two required Psets ("Pfd_IndoorAerosolModeling") was redefined as part of this study, since the associated attributes for an IAM have not yet been standardized. Finally, the developed BIM-integrated IAM was validated on an example building located in Cologne-Mülheim Germany, where a constant PM10 outdoor concentration of CO = 61.00 μg/m³ were assumed. Based on this, it was possible to automatically calculate the occurring indoor concentrations and the time histories of the airborne particle mass concentrations over a selected period of seven minutes (t = 420s) for the fractions PM10 (Cm,PM10(t) = 1.72 μg/m³), PM2.5 (Cm,PM2.5(t) = 1.40 μg/m³), thoracic (Cm,thoracic(t) = 1.66 μg/m³) and high risk respirable (Cm,hrr(t) = 1.31 μg/m³).

Citation: IAQ 2020: Indoor Environmental Quality

See more

Also Bought By Customers

  • 2242199

    Energy Efficient IAQ Management in residential buildings
    Priced From $16.00

  • 2242202

    Assessment of Wind Impact on Building Air Leakage Measure...
    Priced From $15.00

  • 2242204

    Breathing: A New High Efficient Ventilation Concept for N...
    Priced From $15.00

  • 2500546

    Coupling of Air Multizone and Thermal Multizone Models in...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > Topical Conferences > IAQ 2020: Indoor Environmental Quality

Order Options

Delivery Options
Price: $15.00
Available for Immediate Download

Product Details

Published:

2021

Number of Pages:

8

File Size:

1 file

Product Code(s):

D-IAQ-20-C-05

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/bim-integrated-indoor-aerosol-modeling-based-on-outdoor-particles-in-germany?product_id=2242203
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463803940
Order #: None
Cookies: YES
×