accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. BS EN 60079-10-1:2015

BS EN 60079-10-1:2015 Historical

1912752  Preview

Explosive atmospheres-Classification of areas. Explosive gas atmospheres

standard by British-Adopted European Standard , 12/31/2016

This document has been replaced. View the most recent version.

Track This

Full Description

BS EN 60079-10-1:2015 is concerned with the classification of areas where flammable gas or vapour hazards may arise and may then be used as a basis to support the proper selection and installation of equipment for use in hazardous areas.

It is intended to be applied where there may be an ignition hazard due to the presence of flammable gas or vapour, mixed with air, but it does not apply to:
  • mines susceptible to firedamp;
  • the processing and manufacture of explosives;
  • catastrophic failures or rare malfunctions which are beyond the concept of abnormality dealt with in this standard (see 3.7.3 and 3.7.4);
  • rooms used for medical purposes;
  • commercial and industrial applications where only low pressure fuel gas is used for appliances e.g. for cooking, water heating and similar uses, where the installation is compliant with relevant gas codes;
  • domestic premises;
  • where a hazard may arise due to the presence of combustible dusts or combustible flyings but the principles may be used in assessment of a hybrid mixture (refer also IEC 60079-10-2).
NOTE Additional guidance on hybrid mixtures is provided in Annex I.

Flammable mists may form or be present at the same time as flammable vapour. In such case the strict application of the details in this standard may not be appropriate. Flammable mists may also form when liquids not considered to be a hazard due to the high flash point are released under pressure. In these cases the classifications and details given in this standard do not apply. Information on flammable mists is provided in Annex G.

For the purpose of this standard, an area is a three-dimensional region or space.

Atmospheric conditions include variations above and below reference levels of 101,3 kPa (1 013 mbar) and 20 °C (293 K), provided that the variations have a negligible effect on the explosion properties of the flammable substances.

In any process plant, irrespective of size, there may be numerous sources of ignition apart from those associated with equipment. Appropriate precautions will be necessary to ensure safety in this context. This standard is applicable with judgement for other ignition sources.

This standard does not take into account the consequences of ignition of an explosive atmosphere.


Cross References:
IEC 60079-0
EN 60079-0
IEC 60079-14
EN 60079-14
IEC 60079-10-2
EN 60079-10-2
IEC 61285:2004
EN 61285:2004
IEC 60079-20-1
EN 60079-20-1
IGEM/SR/25:2010
API 581:2000
API 581:2008
BS 5925:1991
IEC 60050
EN 1127-1:2010
CEI 31-35:2011
CPR-14E:1997


All current amendments available at time of purchase are included with the purchase of this document. See more

Also Bought By Customers

  • 1104454

    BS 5925:1991
    Priced From $368.30

  • 1894440

    BS EN 61285:2015
    Priced From $279.40

  • 2564831

    BS EN 50104:2019+A1:2023
    Priced From $327.66

  • 1211876

    BS PD CLC/TR 50426:2004
    Priced From $419.10

 

Document History

  1. BS EN IEC 60079-10-1:2021

    April 2021
    Explosive atmospheres-Classification of areas. Explosive gas atmospheres

    • Most Recent  Most Recent
  2. BS EN 60079-10-1:2015

    You are currently viewing this product 👀 currently
    viewing

    December 2016
    Explosive atmospheres-Classification of areas. Explosive gas atmospheres

    • Historical Version
  3. BS EN 60079-10-1:2009

    April 2009
    Explosive atmospheres-Classification of areas. Explosive gas atmospheres

    • Historical Version
  4. BS 06/30153066 DC

    July 2006
    BS IEC 60079-10-1. Explosive atmospheres. Part 10-1. Classification of areas. Explosive gas atmospheres

    • Historical Version
  5. BS EN 60079-10:2003

    April 2003
    Electrical apparatus for explosive gas atmospheres-Classification of hazardous areas

    • Historical Version
  6. BS EN 60079-10:1996

    May 1996
    Electrical apparatus for explosive gas atmospheres-Classification of hazardous areas

    • Historical Version
  7. BS 5345-2:1983

    April 1983
    Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture)-Classification of hazardous areas

    • Historical Version

Browse related products from British-Adopted European Standard

  • BSI Group > 13:ENVIRONMENT. HEALTH PROTECTION. SAFETY > 13.230:Explosion protection
  • BSI Group > 29:ELECTRICAL ENGINEERING > 29.260: Electrical equipment for working in special conditions > 29.260.20:Electrical apparatus for explosive atmospheres

Order Options

Delivery Options
Price: $419.10
Available for Immediate Download

Product Details

Published:

12/31/2016

ISBN(s):

9780580969485, 9780580798733

Number of Pages:

114

File Size:

1 file

Product Code(s):

30353978, 30353978, 30267618

Note:

This product is restricted and cannot be purchased in the following countries Ukraine, Russia, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
Printed Edition + PDF
A combination of a Hard Copy product that is mailed and an electronic product such as a PDF or SPDF (Secure PDF). Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/bs-en-60079-10-1-2015?product_id=1912752
Referrer: Direct Navigation
IP: 216.73.216.127
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463748967
Order #: None
Cookies: YES
×