accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. Buildings XI Conference -- Experimental and Numerical Examination of the Thermal Transmittance of High Performance Window Frames

Buildings XI Conference -- Experimental and Numerical Examination of the Thermal Transmittance of High Performance Window Frames ✓ Most Recent

1785354

Conference Proceeding by ASHRAE , 2010

Arild Gustavsen, PhD, Member ASHRAE; Howdy Goudey; Dariush Arasteh, PE, Member ASHRAE; Sivert Uvsl,kk; Goce Talev; Bj,rn Petter Jelle, PhD; Christian Kohler, Member ASHRAE

Track This

Full Description

While window frames typically represent 20%–30% of the overall window area, their impact on the total window heat transfer rates may be much larger. This effect is even greater in low-conductance (highly insulating) windows that incorporate very low conductance glazings. Developing low-conductance window frames requires accurate simulation tools for product research and development.

The Passivhaus Institute in Germany states that windows (glazing and frames, combined) should have U-factors not exceeding 0.80 W/(m2·K). This has created a niche market for highly insulating frames, with frame U-factors typically around 0.7-1.0 W/ (m2·K). The U-factors reported are often based on numerical simulations according to international simulation standards. It is prudent to check the accuracy of these calculation standards, especially for high-performance products, before more manufacturers begin to use them to improve other product offerings.

In this paper, the thermal transmittance of five highly insulating window frames (three wooden frames, one aluminum frame, and one polyvinyl chloride frame), found from numerical simulations and experiments, are compared. Hot box calorimeter results are compared with numerical simulations according to ISO 10077-2 and ISO 15099 (ISO 2003a, 2003b). In addition, computational fluid dynamics simulations were carried out in order to use the most accurate tool available to investigate the convection and radiation effects inside the frame cavities.

Our results show that available tools commonly used to evaluate window performance, based on ISO standards, give good overall agreement, but specific areas need improvement.

See more

Also Bought By Customers

  • 1776726

    Buildings XI Conference -- A Sound Indoor Climate for a M...
    Priced From $16.00

  • 1776737

    Buildings XI Conference -- Mold Growth Modeling of Buildi...
    Priced From $16.00

  • 1776745

    Buildings XI Conference -- Innovative Concepts for a Set ...
    Priced From $16.00

  • 1776750

    Buildings XI Conference -- Moisture Transport by Osmotic ...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > Topical Conferences > Buildings XI: Thermal Performance of the Exterior Envelopes of Whole Buildings

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2010

Number of Pages:

12

File Size:

1 file

Product Code(s):

D-BUILDINGSXI-173

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/buildings-xi-conference-experimental-and-numerical-examination-of-the-thermal-transmittance-of-high-performance-window-frames?product_id=1785354
Referrer: Direct Navigation
IP: 216.73.216.61
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463810538
Order #: None
Cookies: NO
×