accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. Buildings XI Conference -- Influence of New External Protective Glazing on Historic Painted Windowpanes in Medieval Churches

Buildings XI Conference -- Influence of New External Protective Glazing on Historic Painted Windowpanes in Medieval Churches ✓ Most Recent

1776757

Conference Proceeding by ASHRAE , 2010

Georg-Wilhelm Mainka; Heiko Winkler

Track This

Full Description

In an effort to protect interior painted glass windows (not colorful stained glass) in medieval churches against climatic and mechanical attack, an additional glazing was installed on the exterior at a given distance to the existing glazing. To determine whether this action may threaten the paint in any way, various sensors were installed at specific places around one window each at the upper northern and southern windows of St. Mary’s church in Rostock, Germany, while general restoration work was in progress and the necessary scaffolding was available.

Hourly data of the 32 sensors were collected over one year and then supplemented by the climate data of a nearby national weather station. Collection of data will continue. The results of the measurements show that natural convection exists in the space between the glazings. This space is equipped with apertures at the bottom and top and ventilated towards the indoor climate, depending on the exterior temperature and solar radiation. Short-time condensation occurs at both sides of the interior glazing. After the test period, only a few microorganisms were found on the paint.

The investigation indicates that it is essential to ventilate the space between glazings with upper and lower gaps, but to the inside rather than to the outside (as is usual with ventilated facades). The outside protective glazing has to be airtight.

See more

Also Bought By Customers

  • 1770852

    Buildings XI Conference -- Hygrothermal Performance Optim...
    Priced From $16.00

  • 1776717

    Buildings XI Conference -- Hygrothermal Performance of Fl...
    Priced From $16.00

  • 1776732

    Buildings XI Conference -- Indoor Hygrothermal Conditions...
    Priced From $16.00

  • 1776746

    Buildings XI Conference -- Cellular Glass Aggregate Servi...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > Topical Conferences > Buildings XI: Thermal Performance of the Exterior Envelopes of Whole Buildings

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2010

File Size:

1 file

Product Code(s):

D-BUILDINGSXI-31

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/buildings-xi-conference-influence-of-new-external-protective-glazing-on-historic-painted-windowpanes-in-medieval-churches?product_id=1776757
Referrer: Direct Navigation
IP: 216.73.216.4
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463691752
Order #: None
Cookies: YES
×