accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. C22 -- Reducing HVAC Energy Consumption Through Optimal Sub-Zoning Considering Occupant-Centric Control (OCC)

C22 -- Reducing HVAC Energy Consumption Through Optimal Sub-Zoning Considering Occupant-Centric Control (OCC) ✓ Most Recent

2523010

Conference Proceeding by ASHRAE , 2022

Jeslu Celine Jacob, B.Arch., Student Member ASHRAE; Debapratim Pandit, Ph.D.; Joy Sen, Ph.D.

Track This
👥 Multi-User PDF
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

Improving thermal zoning is a significant means to reduce HVAC energy consumption and improve thermal comfort. Virtual division of super-zones (space bound by physical partitions) into zones (area catered by each air handling unit (AHU)) and sub-zones (regions catered by each diffuser) are gaining popularity for commercial buildings such as open-plan offices with occupant-centric control (OCC). Since thermal coupling from adjacent sub-zones are prominent in such virtual divisions, unplanned sub-zones can lead to energy wastage. Architects and HVAC designers sometimes use their domain knowledge to delineate these zones based on their thermal and functional requirements, occupancy schedule, and system capabilities. Current literature, however, does not address a systematic method of sub-zoning or its optimal size. Our work addresses this gap by exploring a method of parameterized sub-zoning. The effect of spatial parameters such as (1) spatial design (2) location of diffusers and (3) thermostats; dynamic parameters such as (4) ambient conditions, (5) occupancy; and HVAC parameters such as (6) type of diffusers and (7) air supply conditions are analyzed using layouts of existing open-plan offices in India. Transient state parametric analysis of sub-zonal conditioning is performed on a typical open-plan office through CFD simulations employing ANSYS fluent after validating the numerical model using experimental results.

Results indicate that (1) planned sub-zonal conditioning can reduce total energy consumption up to 40% despite an increase in return air temperature; (2) Use of setback conditions in unoccupied sub-zones improve cooling time and helps in reducing sharp vertical thermal gradients; (3) Relative location of diffusers and air supply velocity are two parameters that influence the spread of jets and tuning them is critical in sub-zonal OCC. Our findings enhance literature on thermal zoning highlighting the possibilities and limitations of sub-zonal conditioning and highlights the need for integrated architectural and HVAC design.

See more

Also Bought By Customers

Also Bought By Customers…

Browse related products from ASHRAE

  • ASHRAE > Conferences > Topical Conferences > 5th International Conference on Efficient Building Design: Materials and HVAC Equipment Technologies, 2022

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2022

Number of Pages:

10

Units of Measure:

Dual

File Size:

1 file , 2.3 MB

Product Code(s):

D-ICEB22-22

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/c22-reducing-hvac-energy-consumption-through-optimal-sub-zoning-considering-occupant-centric-control-occ?product_id=2523010
Referrer: Direct Navigation
IP: 216.73.216.209
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463994269
Order #: None
Cookies: YES
×