accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CAN/CSA C22.2 NO. 80601-2-12:24

CAN/CSA C22.2 NO. 80601-2-12:24 ✓ Most Recent

2913766  Preview

Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (Adopted ISO 80601-2-12:2023, third edition, 2023-11, with Canadian deviations)

standard by Canadian Standards Association / National Standard of Canada , 07/31/2024

Track This

Full Description

CSA Preface 

This is the third edition of CSA C22.2 No. 80601-2-12, Medical electrical equipment — Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators, which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-12 (third edition, 2023-11). It supersedes the previous edition, published in 2021 as CSA C22.2 No. 80601-2-12 (adopted ISO 80601-2-12:2020). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CSA C22.2 No. 80601-2-12" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, edition 3.2, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health and Well-being. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. 

201.1 Scope and object IEC 60601-1:2005+AMD1:2012+AMD2:2020, Clause 1 applies, except as follows: 201.1.1 Scope Replacement: 

NOTE 1 There is guidance or rationale for this subclause contained in Clause AA.2. 

This document applies to the basic safety and essential performance of a critical care ventilator in combination with its accessories, hereafter referred to as ME equipment: - intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility; 

NOTE 2 For the purposes of this document, such an environment is referred to as a critical care environment. Ventilators for this environment are considered life-sustaining. 

NOTE 3 For the purposes of this document, such a critical care ventilator can provide ventilation during transport within a professional healthcare facility (i.e. be a transit-operable ventilator). 

NOTE 4 A critical care ventilator intended for use in transport within a professional healthcare facility is not considered as an emergency medical services environment ventilator. 

- intended to be operated by a healthcare professional operator; and 

- intended for those patients who need differing levels of support from artificial ventilation including for ventilator-dependent patients. 

A critical care ventilator is not considered to use a physiologic closed-loop-control system unless it uses a physiological patient variable to adjust the artificial ventilation therapy settings. 

This document is also applicable to those accessories intended by their manufacturer to be connected to a ventilator breathing system, or to a ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilator. 

NOTE 5 If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. 

Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005 +AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1. 

NOTE 6 Additional information can be found in IEC 60601-1:2005+AMD1:2012 +AMD2:2020, 4.2. 

This document is not applicable to ME equipment or an ME system operating in a ventilator-operational mode solely intended for patients who are not dependent on artificial ventilation. 

NOTE 7 A critical care ventilator, when operating in such a ventilator-operational mode, is not considered life-sustaining. 

This document is not applicable to ME equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility. This document does not specify the requirements for: 

NOTE 8 See ISO/TR 21954 for guidance on the selection of the appropriate ventilator for a given patient. 

- ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601-2-13; 

- ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601-2-84; 

- ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601-2-72; 

- ventilators or accessories intended for home-care ventilatory support devices, which are given in ISO 80601-2-79 and ISO 80601-2-80; 

- obstructive sleep apnoea therapy ME equipment, which are given in ISO 80601-2-70; 

- continuous positive airway pressure (CPAP) ME equipment. 

- high-frequency ventilators, which are given in ISO 80601-2-87; 

NOTE 9 A critical care ventilator can incorporate high-frequency jet or high-frequency oscillatory ventilator-operational modes. 

- respiratory high-flow therapy equipment, which are given in ISO 80601-2-90; 

NOTE 10 A critical care ventilator can incorporate high-flow therapy operational mode, but such a mode is only for spontaneously breathing patients. 

- oxygen therapy constant flow ME equipment; and - cuirass or "iron-lung" ventilation equipment. 

201.1.2 Object Replacement: 

The object of this document is to establish basic safety and essential performance requirements for a ventilator, as defined in 201.3.306, and its accessories. 

Accessories are included because the combination of the ventilator and the accessories needs to be adequately safe. Accessories can have a significant impact on the basic safety or essential performance of a ventilator. 

NOTE 1 This document has been prepared to address the relevant essential principles[42] and labelling[43] guidances of the International Medical Devices Regulators Forum (IMDRF) as indicated in Annex CC. 

NOTE 2 This document has been prepared to address the relevant essential principles of safety and performance of ISO 16142-1:2016 as indicated in Annex DD. 

NOTE 3 This document has been prepared to address the relevant general safety and performance requirements of European regulation (EU) 2017/745.

See more

Also Bought By Customers

  • 2523331

    CAN/CSA C22.2 NO. 60601-2-39:23
    Priced From $252.00

  • 2259141

    CAN/CSA C22.2 NO. 60601-1-2:16 (R2021) + A1:22 (CONSOLIDA...
    Priced From $765.00

  • 1984875

    CSA PLUS 14001
    Priced From $100.00

  • 2031537

    CSA C22.2 NO. 60601-2-28:18 (R2023)
    Priced From $178.00

 

Document History

  1. CAN/CSA C22.2 NO. 80601-2-12:24

    You are currently viewing this product 👀 currently
    viewing

    July 2024
    Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (Adopted ISO 80601-2-12:2023, third edition, 2023-11, with Canadian deviations)

    • Most Recent  Most Recent
  2. CAN/CSA C22.2 NO. 80601-2-12:21

    July 2021
    Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (ISO 80601-2-12:2020, MOD)

    • Historical Version
  3. CAN/CSA C22.2 NO. 80601-2-12:12 (R2017)

    November 2012
    Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (Adopted ISO 80601-2-12-:2011, first edition, 2011-04-15, with Canadian deviations, including adopted technical corrigendum 1:2011 to ISO 80601-2-12:2011)

    • Historical Version

Browse related products from Canadian Standards Association / National Standard of Canada

  • CSA Group > Health Care and Medical Devices > Applications of Electricity in Health Care

Order Options

Delivery Options
Price: $330.00
Available for Immediate Download

Product Details

Edition:

3rd

Published:

07/31/2024

ISBN(s):

9781488351273

Number of Pages:

181

File Size:

1 file

Product Code(s):

2431384, 2431500, 2431384, 2431500

Note:

This product is restricted and cannot be purchased in the following countries Russia, Ukraine, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/can-csa-c22-2-no-80601-2-12-24?product_id=2913766
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463798409
Order #: None
Cookies: NO
×