accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CH-09-031 (RP-1292) -- Modeling the Performance of Single-Duct VAV Systems that Use Fan Powered Terminal Units

CH-09-031 (RP-1292) -- Modeling the Performance of Single-Duct VAV Systems that Use Fan Powered Terminal Units ✓ Most Recent

1713416

Conference Proceeding by ASHRAE , 2009

Michael A. Davis; John A. Bryant, PhD, PE; Dennis L. O'Neal, PhD, PE; Andrew Cramlet

Track This
👥 Multi-User PDF
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

This paper is based on findings resulting from ASHRAE Research Project RP-1292.

Variable Air Volume (VAV) systems are commonly used to maintain space comfort in commercial buildings. Single-Duct VAV (SDVAV) systems often use Fan-Powered Terminal Units (FPTU) to control the amount of conditioned air that is delivered to a zone to maintain space conditions. A model was developed to evaluate the operation of a SDVAV system using Series and/or Fan Powered Terminal Units. The procedure used to model the system is described in this paper as are the equations used to model all non-zone level components in the system. The SDVAV system model was verified in the laboratory using a test stand that supported the operation of a three zone system using both series and parallel FPTU. The test stand was set up to mimic the operating points as predicted by the model. System operation was measured and then compared to the predicted values. The details of the model verification are described in another paper.

Units: Dual

 

See more

Also Bought By Customers

Also Bought By Customers…

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2009 Winter Conference, Chicago, IL > Transactions 2009, Vol. 115, pt. 1 > Technical Papers
  • ASHRAE > Transactions > Transactions 2009, Vol. 115, pt. 1 > Technical Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2009

Number of Pages:

6

File Size:

1 file , 1.6 MB

Product Code(s):

D-CH-09-031

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/ch-09-031-rp-1292-modeling-the-performance-of-single-duct-vav-systems-that-use-fan-powered-terminal-units?product_id=1713416
Referrer: Direct Navigation
IP: 216.73.216.209
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463994274
Order #: None
Cookies: YES
×