accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CH-99-16-3 -- Hot Water Use at Coin Laundries

CH-99-16-3 -- Hot Water Use at Coin Laundries ✓ Most Recent

1711105

Conference Proceeding by ASHRAE , 1999

Andrew Lowenstein, Ph.D.; Carl C. Hiller, Ph.D, P.E.

Track This

Full Description

Detailed data on hot water use for one year are presented for two coin laundries. The first is a three-machine laundry that serves half of a 50-unit apartment house, and the second is an eight-machine laundry that serves an 82-unit apartment house. For the smaller laundry, the maximum possible demand - i.e., three machines simultaneously filling with hot water - occurred more than once per month. For the larger laundry, the maximum instantaneous demand was equivalent to four machines simultaneously filling with hot water. At this site, the shortest interval in which hot water use equalled that for all eight machines running hot washes was 35 minutes. The data on hot water use for the two laundries were used to validate a methodology for sizing hot water heaters that had been presented at an ASHRAE Symposium (Hiller 1998). This methodology, which accounts for heating rate, storage capacity, and water temperatures, successfully "predicted" the conditions when the water heaters would and would not be adequate for the measured loads. The data are an important part of ongoing efforts to characterize the highly diverse "universe" of hot water use in commercial buildings.

Units: I-P

See more

Also Bought By Customers

  • 1711072

    CH-99-07-1 -- Dilution Calculations for Determining Labor...
    Priced From $16.00

  • 1711075

    CH-99-08-1 -- Smoke Movement and Detector Activation in H...
    Priced From $16.00

  • 1711076

    CH-99-08-2 (RP-899) -- Large-Scale Physical Model Studies...
    Priced From $16.00

  • 1711082

    CH-99-10-2 -- Simple Absorption Heat Pump Modules for Sys...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 1999 Winter Conference, Chicago, IL > Transactions 1999, Vol. 105, pt. 1 > Symposium Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

1999

Number of Pages:

7

File Size:

1 file

Product Code(s):

D-7616

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/ch-99-16-3-hot-water-use-at-coin-laundries?product_id=1711105
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463805005
Order #: None
Cookies: YES
×