accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA ANSI Z21.11.2-2013

CSA ANSI Z21.11.2-2013 Historical

1864033  Preview

Gas-Fired Room Heaters - Volume II, Unvented Room Heaters

standard by CSA Group , 08/01/2013

This document has been replaced. View the most recent version.

Track This

Full Description

Preface

This is the twenty-seventh edition of ANSI Z21.11.2, Gas-fired room heaters, volume II, unvented room heaters. It supersedes the previous editions published in 2011, 2007, 2000, 1996, 1992, 1989, 1983, 1978, 1974, 1971, 1967, and 1962.

Scope

1.1
This standard applies to newly produced gas-fired unvented room heaters and gas-fired unvented decorative room heaters for connection to the house fuel supply system (see Clause 3), hereinafter referred to as room heaters or appliances, constructed entirely of new, unused parts and materials, having input ratings up to and including 40,000 Btu/hr (11 723 W) except:

a) Unvented room heaters suitable for installation in bedrooms shall have input ratings of 10,000 Btu/hr (2 931 W) or less; and

b) Unvented room heaters suitable for installation in bathrooms shall have input ratings of 6000 Btu/hr (1 758 W) or less.

1.2
This standard covers unvented room heaters and gas-fired unvented decorative room heaters that comply with either of the following types:

a) shipped from the factory equipped specifically for use with one gas only. Field conversion of gas types by any means including the use of a kit shall not be permitted; or

b) a universal unvented room heater shipped from the factory equipped with a switching means for selecting the type of gas to which it is being connected.

1.3
Unvented room heaters are:

a) for use with natural gas;

b) for use with manufactured gas;

c) for use with mixed gas;

d) for use with liquefied petroleum/propane gases;

e) for use with LP gas-air mixtures; and

f) for manufactured (mobile) home aftermarket installation for use with natural gas only or for use with liquefied petroleum/propane gases only.

1.4
Universal unvented room heaters are:

a) for use with propane and for use with natural gas when provision is made for a switching means from one gas to the other; and

b) for manufactured (mobile) home or mobile home aftermarket installation for use with propane and for use with natural gas when provision is made for a switching means from one gas to the other (see Clause 4.1.4).

1.5
Unvented room heaters for installation in bathrooms shall be wall-mounted. Unvented room heaters for installation in bedrooms shall be wall mounted or for installation in solid-fuel burning fireplaces. An unvented gas log (see Clause 3), provided with means for mounting the burner base assembly to the floor of the solid-fuel burning fireplace, shall be considered as complying with the wall-mounted requirement for installation in bedrooms or bathrooms.

1.6
The construction of unvented room heaters for use with the above-mentioned gases is covered under Clause 4.

1.7
The performance of unvented room heaters for use with the above- mentioned gases is covered under Clause 5.

1.8
This standard covers appliances shipped from the factory equipped specifically for one gas only. Field conversion of gas types shall not be permitted.

1.9
Special construction provisions applicable to room heaters for manufactured (mobile) home aftermarket installation are outlined under Clauses 1.3(f), 4.20.4 and 4.21.2(j).

1.10
If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.

1.11
All references to psi throughout this standard are to be considered gage pressure unless otherwise specified.

1.12
Clause 2 contains a list of standards referenced in this standard, and sources from which these reference standards may be obtained.

See more

Also Bought By Customers

  • 1758266

    CSA ANSI Z21.23-2010 (R2020)
    Priced From $430.00

  • 2582485

    CSA /ANSI Z21.42:24/CSA 2.15:24
    Priced From $500.00

  • 2076754

    CSA 2.22:19/ANSI Z21.50:19 (R2024)
    Priced From $838.00

  • 1943373

    CSA Z21.60-2017 (R2021)/CSA 2.26-2017 (R2021)
    Priced From $495.00

 

Document History

  1. CSA ANSI Z21.11.2:19 (R2024)

    July 2019
    Gas-fired room heaters, volume II, unvented room heaters

    • Most Recent  Most Recent
  2. CSA ANSI Z21.11.2-2016

    November 2016
    Gas-Fired Room Heaters - Volume II, Unvented Room Heaters

    • Historical Version
  3. CSA ANSI Z21.11.2-2013

    You are currently viewing this product 👀 currently
    viewing

    August 2013
    Gas-Fired Room Heaters - Volume II, Unvented Room Heaters

    • Historical Version
  4. CSA ANSI Z21.11.2-2011

    September 2011
    Gas-Fired Room Heaters - Volume II, Unvented Room Heaters

    • Historical Version
  5. CSA ANSI Z21.11.2-2007

    March 2007
    Gas-Fired Room Heaters - Volume II, Unvented Room Heaters

    • Historical Version
  6. CSA ANSI Z21.11.2-2002

    October 2002
    Gas-Fired Room Heaters - Volume II, Unvented Room Heaters

    • Historical Version

Browse related products from CSA Group

  • CSA Group > Energy > Gas Equipment > Gas-Fired Domestic and Commercial Heating Equipment and Air

Order Options

Delivery Options
Price: $510.00
Available for Immediate Download

Product Details

Edition:

27th

Published:

08/01/2013

ISBN(s):

9781771393522

Number of Pages:

141

File Size:

1 file

Product Code(s):

2422746, 2422746

Note:

This product is restricted and cannot be purchased in the following countries Russia, Ukraine, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-ansi-z21-11-2-2013?product_id=1864033
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463798810
Order #: None
Cookies: YES
×