accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA C22.2 NO. 0.22:11 (R2021)

CSA C22.2 NO. 0.22:11 (R2021) ✓ Most Recent

1810877  Preview

Evaluation methods for arc resistance ratings of enclosed electrical equipment, Includes Update No. 1 (2012)

standard by CSA Group , 08/01/2011

Track This

Full Description

Preface:
This is the first edition of CSA C22.2 No. 0.22, Evaluation methods for arc resistance ratings of enclosed electrical equipment, one of a series of Standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code.

This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group.

Scope:

1.1
This Standard establishes methods by which metal-enclosed equipment can be tested for resistance to the effects of arcing resulting from an internal fault.

1.2
This Standard applies only to indoor and outdoor equipment that uses air as the primary insulating medium and that is rated up to 46 kV ac.
Note: Building size and construction are factors to be considered in indoor applications. These factors are not addressed in this Standard.

1.3
The tests and assessments described in this Standard are applicable only to arcing faults occurring entirely in air within the enclosure when all doors and covers are properly secured.

1.4
This Standard does not apply to arcing faults that occur within a component of the assembly, such as instrument transformers, sealed interrupting devices, or fuses.

1.5
Metal-enclosed switchgear designs that meet the requirements of this Standard are referred to as arc-resistant switchgear. Motor control designs that meet the requirements of this Standard are referred to as arc-resistant motor control.
Note: Annex C provides additional information on the consequences of internal arc faults, equipment qualified to this Standard, relevance of tests, and the application of this Standard.

1.6
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

1.7
The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. See more

Also Bought By Customers

  • 2259129

    CAN/CSA C22.2 NO. 0.17:22
    Priced From $200.00

  • 2111436

    CSA C22.2 NO. 0:20 (R2025)
    Priced From $210.00

  • 1909668

    CSA C22.2 NO. 0.2:16 (R2025)
    Priced From $104.00

  • 2035391

    CSA C22.2 No. 0.12:19 (R2024)
    Priced From $113.00

Browse related products from CSA Group

  • CSA Group > Electrical > Canadian Electrical Code Part II-General Requirements

Order Options

Delivery Options
Price: $203.00
Available for Immediate Download

Product Details

Edition:

1st

Published:

08/01/2011

ISBN(s):

9781554916924

Number of Pages:

50

File Size:

1 file

Product Code(s):

2421338, 2421338

Note:

This product is restricted and cannot be purchased in the following countries Russia, Ukraine, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-c22-2-no-0-22-11-r2021?product_id=1810877
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463798381
Order #: None
Cookies: YES
×