accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA C22.2 NO. 65:25

CSA C22.2 NO. 65:25 ✓ Most Recent

2932814  Preview

Wire connectors (Trinational standard with NMX-J-543-ANCE-2025 and UL 486A-486B)

standard by CSA Group , 03/13/2025

Track This

Full Description

Preface 

This is the harmonized ANCE, CSA Group, and ULSE standard for Wire Connectors . It is the fifth edition of NMX-J-543-ANCE, the seventh edition of CSA C22.2 No. 65, and the fourth edition of UL 486A-486B. This edition of NMX-J-543-ANCE supersedes the previous edition published on July 20, 2023. This edition of CSA C22.2 No. 65 supersedes the previous edition published on January 11, 2013 and April 27, 2018. This edition of UL 486A-486B supersedes the previous edition published on April 27, 2018. This harmonized standard was prepared by the Association of Standardization and Certification (ANCE), CSA Group, and ULSE Inc. (ULSE). The efforts and support of the Technical Harmonization Committee for Connectors, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. The present Mexican standard was developed by the SC 20D – Conectadores part of the CT 20 – Conductores from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the connectors manufacturers and users. This standard was reviewed by the CSA Integrated Committee on Electrical Connectors, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. 

Scope 

1.1 This Standard applies to single-polarity connectors for use with all alloys of copper or aluminum, or copper-clad aluminum conductors, or all three, for providing contacts between current-carrying parts, in accordance with the Canadian Electrical Code, Part I, CSA C22.1, in Canada, the National Electrical Code, NFPA 70, in the United States of America, or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico, as follows: NOTE: Copper-clad aluminum conductors are for use only in the United States in accordance with the National Electrical Code, NFPA 70. a) Pressure wire connectors intended to hold one or more conductor(s); b) Connectors intended for use in appliances and equipment that comply with the requirements for such appliances and equipment; c) Soldering connectors; d) Splicing wire connectors intended for use with 4 AWG (21.2 mm 2 ) or larger conductors; NOTE: A splicing wire and cable connector taking a range of conductor sizes may include conductor sizes smaller than 4 AWG (21.2 mm 2 ). e) Neutral bars; f) Uninsulated connectors that are used in circuits rated 35 000 V and below; g) Ampere-rated connectors not intended for general use; h) Insulation piercing connectors; i) Exothermically welded wire connectors; j) Pressure connectors and devices for splices and taps installed on service conductors; k) Multi-tap connectors; and l) Run and tap connectors. 

1.2 Connectors covered by this Standard are also suitable for use with conductors that are prepared using ferrules evaluated in accordance with CSA C22.2 No. 291-14 / UL 486F, or wire connector adapters evaluated in accordance with this Standard, under the following conditions: a) Ferrules and adapters are applied in accordance with their ratings and installation instructions. b) The length of exposed conductive material maintains the strip lengths required by the connector manufacturer. 

1.3 This Standard is intended for connectors suitable for use with conductors in the size ranges as follows: a) Aluminum: 1) 12 AWG (3.3 mm 2 ) and 10 AWG (5.3 mm 2 ) solid; 2) 12 AWG (3.3 mm 2 ) to 2 000 kcmil (1 010 mm 2 ) stranded, Class B concentric, compressed, and compact; and 3) 12 AWG (3.3 mm 2 ) to 1 000 kcmil (508 mm 2 ) stranded single input wire (SIW). b) Copper-clad aluminum: 1) In Canada, this construction is not allowed. 2) In Mexico, this construction is not allowed. 3) In the United States: i) 12 AWG (3.3 mm 2 ) and 10 AWG (5.3 mm 2 ) solid; and ii) 12 AWG (3.3 mm 2 ) to 2 000 kcmil (1 010 mm 2 ) stranded, Class B concentric, compressed, and Class C concentric. c) Copper: 1) 30 AWG (0.05 mm 2 ) to 10 AWG (5.3 mm 2 ) solid; and 2) 30 AWG (0.05 mm 2 ) to 2 000 kcmil (1 010 mm 2 ) stranded, Class B concentric and compressed, and Class C concentric. d) Compact-stranded copper conductors: 1) In Canada for 8 AWG (8.4 mm 2 ) and larger; 2) In the United States for 2 AWG (33.6 mm 2 ) and larger; and 3) In Mexico for 8 AWG (8.4 mm 2 ) and larger. e) Rigid (solid and stranded) metric wire sizes, Classes 1, 2, 5, and 6, in the range of 0.5 – 2 500 mm 2 , in addition to AWG/kcmil sizes, with AWG/kcmil ratings mandatory and metric wire ratings optional. NOTE 1: Metric wire sizes are based on the IEC Standard for Conductors of Insulated Cables, IEC 60228. NOTE 2: For example, a connector rated for 6 AWG – 350 kcmil may be additionally rated for 16 – 185 mm 2 . See Annex B for example. f) Other class and strand configurations as indicated by marking. 

1.4 This Standard is intended for connectors suitable for currents not exceeding the ampacity of insulated conductors rated 75 °C or 90 °C in accordance with the rating of the connector, if provided. 

1.5 These requirements cover insulated connectors, insulating caps, and covers intended for use at 2 000 volts or less and uninsulated connectors for use in general use circuits rated 35 000 volts nominal or less. In Canada, uninsulated connectors may also be used in applications up to 5 000 volts phase-to-phase where allowed and installed in accordance with Section 36 of the Canadian Electrical Code, Part I, CSA C22.1. For products intended for use in Canada, general requirements are given in CSA C22.2 No. 0. 

1.6 This Standard does not apply to: a) Insulated connectors for voltage levels above 2 000 V; b) Manual twist-on connectors; c) Built-in terminal connectors in devices rated less than 30 A intended for outlet box mounting or having provision for stress relief; d) Flat quick connect terminals; e) Wire binding screw terminals; and f) Bare or covered ferrules intended for use with 1/0 – 20 AWG stranded copper conductors.

See more

Also Bought By Customers

  • 1598785

    CSA C22.2 NO. 2459-08 (R2022)
    Priced From $557.00

  • 2253534

    CSA C22.2 NO. 41:22
    Priced From $500.00

  • 2569307

    CSA C22.2 NO. 188:23
    Priced From $329.00

  • 2912287

    CSA C22.2 NO. 355:24
    Priced From $150.00

 

Document History

  1. CSA C22.2 NO. 65:25

    You are currently viewing this product 👀 currently
    viewing

    March 2025
    Wire connectors (Trinational standard with NMX-J-543-ANCE-2025 and UL 486A-486B)

    • Most Recent  Most Recent
  2. CAN/CSA C22.2 NO. 65-18 (R2022)

    April 2018
    Wire connectors (Trinational standard with NMX-J-543-ANCE and UL 486A-486B), Includes Update No. 1 (2019), Update No. 2 (2021), and Update No. 3 (2023)

    • Historical Version
  3. CSA C22.2 NO. 65-13 (R2018)

    January 2013
    Wire Connectors (Tri-national standard, with UL 486A-486B and NMX-J-543- ANCE), Includes Update No. 1 (2013), Update No. 2 (2016)

    • Historical Version
  4. CAN/CSA C22.2 NO. 65-03 (R2008)

    May 2005
    Wire Connectors (Tri-National standard, with UL 486A-486B and NMX-J-543-ANCE-03). Includes Update Nos. 1 and 2 (2006), Update No. 3 (2010), Update No. 4 (2010

    • Historical Version
  5. CSA C22.2 NO. 65-93 (R1999)

    May 2000
    Wire Connectors

    • Historical Version

Browse related products from CSA Group

  • CSA Group > Electrical > Wiring Products > Electrical Connectors

Order Options

Delivery Options
Price: $570.00
Available for Immediate Download

Product Details

Edition:

7th

Published:

03/13/2025

ISBN(s):

9781488351112

Number of Pages:

109

File Size:

1 file

Product Code(s):

2431481, 2431481

Note:

This product is restricted and cannot be purchased in the following countries Russia, Ukraine, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-c22-2-no-65-25?product_id=2932814
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463798648
Order #: None
Cookies: YES
×