accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA G40.20-04/G40.21-04 (R2009)

CSA G40.20-04/G40.21-04 (R2009) Historical

1153107  Preview

General Requirements for Rolled or Welded Structural Quality Steel/Structural Quality Steel

standard by CSA Group , 02/01/2004

This document has been replaced. View the most recent version.
Track This
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

This is a text searchable PDF

G40.20-04 General requirements for rolled or welded structural quality steel

1 Scope

1.1 This Standard outlines the requirements that apply, unless otherwise specified in a purchase order or individual standard, to structural quality steel plates, shapes, sheet, sheet piling, cold-formed channels, hollow sections, Z sections, and bars conforming to the requirements of CSA G40.21. Tables 11(a) to (h) of CSA G40.21 provide information on the dimensions and mass (weight) per unit length of structural shapes and sections commonly used in the construction of steel buildings and bridges.

1.2 In CSA Standards, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Legends to equations and figures are considered requirements.

1.3 The values stated in either SI (metric) or yard/pound units are to be regarded as standard. Within the text, the yard/pound units are shown in parentheses. The values stated in each system are not exact equivalents; each system must be used independently. Combining values from the two systems can result in nonconformance with this Standard.

G40.21-04 Structural quality steel

1 Scope

1.1 This Standard covers structural quality steel plates, shapes, hollow sections, sheet, sheet piling, cold-formed channels, Z sections, and bars for general construction and engineering purposes.

1.2 A number of strength levels are available under this Standard and are designated by the minimum yield strength in MPa (ksi). The common grades, types, and strength levels are shown in Table 1. Charpy V-notch categories are shown in Table 9. The purchaser specifies the grade and, if applicable, the category.

1.3 The following types of steel are covered by this Standard:

(a) Type W - Weldable Steel Steels of this type meet specified strength requirements and are suitable for general welded construction where notch toughness at low temperatures is not a design requirement. Applications include buildings, compression members of bridges, etc.

(b) Type WT - Weldable Notch-Tough Steel Steels of this type meet specified strength and Charpy V-notch impact requirements and are suitable for welded construction where notch toughness at low temperature is a design requirement. The purchaser, in addition to specifying the grade, specifies the required category of steel that establishes the Charpy V-notch test temperature and energy level. Applications include primary tension members in bridges and similar elements.

(c) Type R - Atmospheric Corrosion-Resistant Steel Steels of this type meet specified strength requirements. The atmospheric corrosion resistance of these steels in most environments is substantially better than that of carbon structural steels with or without a copper addition.* These steels are welded readily up to the maximum thickness covered by this Standard. Applications include unpainted siding, unpainted light structural members, etc., where notch toughness at low temperature is not a design requirement. *For methods of estimating the atmospheric corrosion resistance of low-alloy steels, see Clause 7.6. When properly exposed to the atmosphere, these steels can be used bare (unpainted) for many applications.

(d) Type A - Atmospheric Corrosion-Resistant Weldable Steel Steels of this type meet specified strength requirements. The atmospheric corrosion resistance of these steels in most environments is substantially better than that of carbon structural steels with or without a copper addition.* These steels are suitable for welded construction where notch toughness at low temperature is not a design requirement. Applications include those similar to Type W steel. *For methods of estimating the atmospheric corrosion resistance of low-alloy steels, see Clause 7.6. When properly exposed to the atmosphere, these steels can be used bare (unpainted) for many applications.

(e) Type AT - Atmospheric Corrosion-Resistant Weldable Notch-Tough Steel Steels of this type meet specified strength and Charpy V-notch impact requirements. The atmospheric corrosion resistance of these steels in most environments is substantially better than that of carbon structural steels with or without a copper addition.* These steels are suitable for welded construction where notch toughness at low temperature is a design requirement. The purchaser, in addition to specifying the grade, specifies the required category of steel that establishes the Charpy V-notch test temperature and energy level. Applications include primary tension members in bridges and similar elements. *For methods of estimating the atmospheric corrosion resistance of low-alloy steels, see Clause 7.6. When properly exposed to the atmosphere, these steels can be used bare (unpainted) for many applications.

(f) Type Q - Quenched and Tempered Low-Alloy Steel Plate Steels of this type meet specified strength requirements. While these steels are weldable, the welding and fabrication techniques are of fundamental importance to the properties of the plate, especially the heat-affected zone. Applications include bridges and similar structures.\

(g) Type QT - Quenched and Tempered Low-Alloy Notch-Tough Steel Plate Steels of this type meet specified strength and Charpy V-notch impact requirements. They provide good resistance to brittle fracture and are suitable for structures where notch toughness at low temperature is a design requirement. The purchaser, in addition to specifying the grade, specifies the required category of steel that establishes the Charpy V-notch test temperature and energy level. While these steels are weldable, the welding and fabrication techniques are of fundamental importance to the properties of the plate, especially the heat-affected zone. Applications include primary tension members in bridges and similar elements.

1.4 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements. Legends to equations and figures are considered requirements.

1.5 The values stated in either SI (metric) or yard/pound units are to be regarded as standard. Within the text, the yard/pound units are shown in parentheses. The values stated in each system are not exact equivalents; each system must be used independently. Combining values from the two systems can result in nonconformance with this Standard.
See more

Also Bought By Customers

Also Bought By Customers…

 

Document History

  1. CSA G40.20-13/G40.21-13 (R2023)

    July 2013
    General Requirements for Rolled or Welded Structural Quality Steel/Structural Quality Steel, Includes Update No. 1 (2014)

    • Most Recent  Most Recent
  2. CSA G40.20-04/G40.21-04 (R2009)

    You are currently viewing this product 👀 currently
    viewing

    February 2004
    General Requirements for Rolled or Welded Structural Quality Steel/Structural Quality Steel

    • Historical Version
  3. CSA G40.20-98/G40.21-98

    March 2000
    General Requirements for Rolled or Welded Structural Quality Steel/Structural Quality Steel

    • Historical Version
  4. CSA G40.20/G40.21-92

    January 1992
    General Requirements for Rolled or Welded Structural Quality Steel / Structural Quality Steels (imperial version) - USE CURRENT EDITION

    • Historical Version

Order Options

Delivery Options
Price: $176.00
Available for Immediate Download

Product Details

Published:

02/01/2004

Number of Pages:

110

File Size:

1 file , 1.1 MB

Product Code(s):

2416784, 2416784

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-g40-20-04-g40-21-04-r2009?product_id=1153107
Referrer: Direct Navigation
IP: 216.73.216.195
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1464074894
Order #: None
Cookies: YES
×