accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA N288.4:19 (R2024)

CSA N288.4:19 (R2024) Historical

2085972  Preview

Environmental monitoring programs at nuclear facilities and uranium mines and mills

standard by CSA Group , 09/01/2019

This document has been replaced. View the most recent version.

Track This

Full Description

Scope:

1.1 Facilities

1.1.1 Types of facilities
This Standard addresses the design and operation of EMPs for nuclear facilities. Note: On-site conventional waste management facilities (e.g., landfills, incinerators, and sewage treatment plants handling non-radioactive material) are included in the scope of this Standard.

1.1.2 Facility lifecycle
The nature and extent of environmental monitoring requirements will change during the lifecycle of the facility.

This Standard addresses monitoring performed during
a) site preparation, construction, and commissioning;
b) operations;
c) decommissioning; and
d) any period of institutional control that might follow closure of the facility.

Notes:
1) In Canada, baseline monitoring prior to the submission of an application for a licence to prepare a site might not be fully addressed by this Standard. For more information on pre-licensing baseline monitoring, see CNSC REGDOC-1.1.1, Section 3.4, Appendix B.3, and Appendix C, CNSC REGDOC-2.9.1, and BCMOE, 2016.
2) Data from baseline monitoring are generally used as an input into the ERA. Many of the recommendations and considerations provided within this Standard are applicable to environmental baseline activities. In addition, pre-licensing baseline data collection ideally places special emphasis on environmental factors and elements that might be carried forward to the EMP.

1.2 Operating conditions

1.2.1 Monitoring during normal operations
The monitoring described in this Standard is applicable where human and/or non-human biota might routinely be exposed to
a) low-level emissions of nuclear and hazardous substances released to the environment as the result of the normal operation of a nuclear facility; or
b) physical stressors imposed on the environment as the result of the normal operation of a nuclear facility.

1.2.2 Monitoring during accidental releases
This Standard does not address acute or high-level exposures that can result from accident scenarios e.g., design basis accidents, beyond design basis accidents), although some parts of this Standard might be applicable to the monitoring of the long-term effect of such an event. In these cases, the operator of the facility is responsible for determining the applicability of the guidance.

1.2.3 Monitoring program boundary
This Standard addresses monitoring conducted in the environment within the spatial boundaries defined in the ERA.

This monitoring starts beyond
a) the final point of control for an airborne or waterborne release; or
b) the facility boundary.

Note: The facility boundary may be the outer wall or foundation of the building housing the licensed activity. In Canada, the facility boundary may be the boundary of the protected area as defined in Section 9 of the Nuclear Security Regulations for nuclear facilities to which those Regulations apply. Monitoring extends out to locations determined in the ERA by receptors and receptor range. The spatial boundaries might be different for each media.

Notes:
1) This Standard does not address effluent monitoring, which involves the monitoring of the release of nuclear and hazardous substances to the environment. See CSA N288.5 for additional information on effluent monitoring programs.
2) This Standard assumes that the exposure to nuclear or hazardous substances by persons working or visiting inside the facility boundary will be controlled through the facility radiation protection program, environmental protection program, or health and safety program.

1.3 Contaminants and physical stressors
This Standard provides guidance on monitoring for the contaminants and physical stressors in environmental media, as identified in the ERA and/or determined by the AHJ. These contaminants and physical stressors can include one or more of the following:
a) hazardous substances such as toxic, corrosive, or environmentally deleterious substances;
b) nuclear substances and radiation; and
c) physical stressors.

1.4 Receptors and biological effects
This Standard provides guidance on designing an EMP that can
a) provide the data necessary to assess potential biological effects on receptors; and
b) measure direct biological effects on receptors.

Notes:
1) Receptors are as identified in the ERA and/or as determined by the AHJ. The receptors can include human or non-human biota.
2) Measurements of effects in non-human biota (measurement endpoints) can occur at the level of an individual organism, a population, or a community. Often measurement endpoints at the individual level are intended to represent the potential for higher level effects (assessment endpoints) that are of primary concern to environment managers.

1.5 Interpretation of data
This Standard provides guidance on the interpretation of data collected by an EMP. However, users are cautioned that AHJs can impose requirements regarding data analysis and interpretation that differ from those described in this Standard. The operator of the nuclear facility is responsible for determining what data analysis and interpretation are necessary to ensure compliance with AHJ requirements.

1.6 Dose assessment
Although one of the objectives of an EMP may be to provide the data required to support radiation dose assessments or assessments of exposure to hazardous substances, this document does not address dose assessment methods for either human or non-human biota.

Note: Assessments of dose/exposure are normally part of the ERA and any subsequent assessments based on environmental monitoring data are ideally done the same way, using CSA N288.6 or equivalent standards and guidance that were used in the ERA or their most recent updates. Monitoring to support dose assessment is further addressed in Clause 7.4.

1.7 Reporting
This Standard provides guidance on reporting the results of an EMP. However, users are cautioned that AHJs may impose reporting requirements that differ from those described in this Standard. The operator of the nuclear facility is responsible for determining the required frequency and content of reports to AHJs necessary to ensure compliance.

1.8 Terminology
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. See more

Also Bought By Customers

  • 1998583

    CSA N287.2-17 (R2022)
    Priced From $890.00

  • 3018118

    CSA N290.13:25
    Priced From $1,190.00

  • 2095524

    CSA N299.1:19 (R2025)
    Priced From $890.00

  • 2212693

    CSA N290.20:21
    Priced From $890.00

 

Document History

  1. CSA N288.4:25

    August 2025
    Environmental monitoring programs at nuclear facilities

    • Most Recent  Most Recent
  2. CSA N288.4:19 (R2024)

    You are currently viewing this product 👀 currently
    viewing

    September 2019
    Environmental monitoring programs at nuclear facilities and uranium mines and mills

    • Historical Version
  3. CSA N288.4-10 (R2015)

    May 2010
    Environmental monitoring programs at Class I nuclear facilities and uranium mines and mills

    • Historical Version
  4. CAN/CSA N288.4-M90 (R2008)

    May 2000
    Guidelines for Radiological Monitoring of the Environment

    • Historical Version

Browse related products from CSA Group

  • CSA Group > Energy > Nuclear

Order Options

Delivery Options
Price: $1,390.00
Available for Immediate Download

Product Details

Edition:

3rd

Published:

09/01/2019

ISBN(s):

9781488322365

Number of Pages:

153

File Size:

1 file

Product Code(s):

2427118, 2427260, 2427260

Note:

This product is restricted and cannot be purchased in the following countries Russia, Ukraine, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-n288-4-19-r2024?product_id=2085972
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463802639
Order #: None
Cookies: YES
×