accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA N290.11:21

CSA N290.11:21 ✓ Most Recent

2230971  Preview

Requirements for reactor heat removal capability during outage of nuclear power plants

standard by CSA Group , 07/01/2021

Track This

Full Description

Preface 

This is the second edition of CSA N290.11, Requirements for reactor heat removal capability during outage of nuclear power plants . It supersedes the previous edition published in 2013. The following are the major changes to this edition: a) updated requirements and specifications for the back-up heat sink and the protection it is to provide; b) provided additional clarification in areas identified by users; and c) improved alignment with current industry standards. The CSA N-Series of Standards provides an interlinked set of requirements for the management of nuclear facilities and activities. CSA N286 provides overall direction to management to develop and implement sound management practices and controls, while the other CSA nuclear Standards provide technical requirements and guidance that support the management system. 

This Standard works in harmony with CSA N286 and does not duplicate the generic requirements of CSA N286; however, it can provide more specific direction for those requirements. This Standard reflects the operating experience of the Canadian nuclear power industry. Users of this Standard are reminded that the design, manufacture, construction, commissioning, operation, and decommissioning of nuclear facilities in Canada are subject to the provisions of the Nuclear Safety and Control Act and its supporting Regulations. 

Scope 

1.1 This Standard covers the design, qualification, installation, commissioning, operation, maintenance, testing, inspection, and documentation requirements for systems providing heat removal from the reactor core to the ultimate heat sink(s) for water-cooled nuclear power plants during outages. 

1.2 This Standard covers only fuel cooling within the reactor core and does not cover spent fuel pool cooling, off-reactor fuelling operations, or the completely defueled core state. 

1.3 This Standard covers all systems that contribute to the transfer of heat by a) conveying heat to the ultimate heat sink; b) providing power or compressed air; c) providing inventory makeup to heat sink systems; or d) monitoring and control. Note: The combination of systems or portions of systems that contribute to these functions are referred to in this Standard as "heat sinks". 

1.4 The term outage refers to the following reactor states: a) a shutdown state where subcriticality is assured by physical means; or Note: For CANDU reactors, this refers to a guaranteed shutdown state. b) critical or sub-critical at any power where the normal (at high power) heat sinks are not the primary heat sinks. Note: Examples of high power heat sinks include steaming of boilers to turbine or condensers. 

1.5 This Standard does not cover requirements for design extension conditions (DEC). Requirements and principles for maintaining fuel cooling for outages during DECs, including requirements for emergency cooling water and power supplies, are covered in CSA N290.16. 

1.6 For the purposes of this Standard, the outage commences when the normal (at high power) heat sinks are no longer the primary heat sinks. The outage is considered to be terminated when the normal (at high power) heat sinks are reestablished as part of the plan to proceed to sustained high power operation. 

1.7 In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

See more

Also Bought By Customers

  • 2576065

    CSA N285.8:23
    Priced From $4,890.00

  • 2095525

    CSA N299.2:19 (R2025)
    Priced From $890.00

  • 1929754

    CSA N290.5-16 (2021)
    Priced From $890.00

  • 2930850

    CSA N294:25
    Priced From $1,290.00

 

Document History

  1. CSA N290.11:21

    You are currently viewing this product 👀 currently
    viewing

    July 2021
    Requirements for reactor heat removal capability during outage of nuclear power plants

    • Most Recent  Most Recent
  2. CSA N290.11-13 (R2019)

    December 2013
    Requirements for reactor heat removal capability during outage of nuclear power plants

    • Historical Version

Browse related products from CSA Group

  • CSA Group > Energy > Nuclear

Order Options

Delivery Options
Price: $690.00
Available for Immediate Download

Product Details

Published:

07/01/2021

ISBN(s):

9781488336317

Number of Pages:

29

File Size:

1 file

Product Code(s):

2429147, 2429149, 2429147, 2429149

Note:

This product is restricted and cannot be purchased in the following countries Russia, Ukraine, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-n290-11-21?product_id=2230971
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463798573
Order #: None
Cookies: YES
×