accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA S37-13

CSA S37-13 Historical

1869686  Preview

Antennas, Towers, and Antenna-Supporting Structures

standard by CSA Group , 11/01/2013

This document has been replaced. View the most recent version.

Track This

Full Description

Preface

This is the seventh edition of CSA Standard S37, Antennas, towers, and antenna-supporting structures. It supersedes the previous editions published in 2001, 1994, 1986, 1981, 1976, and 1965.

Antennas, towers, and antenna-supporting structures comprise a group that can be described as communication structures. They are usually of lattice steel construction, but may be of solid or tubular construction and may use a variety of materials. They may be guyed or self-supporting, and some structures may be mounted on platforms or building rooftops. The principal loads are wind and ice, while earthquake effects require a design check for designated post-critical installations in regions of medium to high seismicity. This Standard is written to address these special characteristics using the applicable sections of other CSA structural design standards. It also refers to the National Building Code of Canada for the specification of seismic spectral accelerations.

Most design standards are written to address the requirements of new structures. The Technical Committee for this Standard has also been concerned about the effect of changes on existing structures. While it is not mandatory to upgrade existing towers when new editions of the Standard are published, communication structures are frequently subject to changes in attached equipment. This necessitates conformance with the current edition. Changes are therefore carefully considered so as not to cause significant economic impact as a result of minor changes in equipment.

The latest amendments to Part II of the Canada Occupational Safety and Health Regulations (COSH) of the Canada Labour Code require that the design and construction of every tower, antenna, and antenna-supporting structure meet the requirements of this Standard as amended from time to time. This requirement may be modified for an antenna if the electronic performance cannot be achieved. Safety of persons who are required to climb a tower is as important a consideration as the safety of the structure; therefore, requirements for ladders, safety devices, platforms, and cages are included as part of this Standard.

This edition of the Standard has undergone an extensive editorial revision to clarify certain clauses and make it more uniform in language. It also introduces mandatory seismic checks for all designated post-critical structures that must remain serviceable immediately after an earthquake.

It has long been recognized that some structures, particularly tall guyed masts, can be subject to dynamic effects that require a more in-depth study of the loads and responses than that provided by static analysis procedures. This Standard does not have mandatory requirements for dynamic analysis, but it does provide a quasi-dynamic patch-loading procedure, which is recommended for the analysis of wind effects on such towers.

CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Bell Mobilite, Nav Canada, Hydro-Quebec, Rogers Communication Partnership, CBC Ontario, NorthWesTel Inc. and Manitoba Hydro.

Scope

1.1 General
This Standard applies to structural antennas, towers, antenna-supporting structures, and roof- and wall-mounted structures, including their components, such as guys and foundations. It covers the structural design, fabrication, and erection of new structures and the modification of existing structures.

1.2 Exclusions
This Standard is not intended to apply to

a) attachment antennas and arrays or assemblies of such antennas; or

b) towers that support attachment antennas, extending less than 15 m above grade, including the height of any structure on which they are mounted.

1.3 Unusual designs and antennas
This Standard covers the requirements for most structural antennas, antenna towers, and antenna-supporting structures, but it is recognized that structures that are unusual with regard to their height or shape, or with regard to the shape and size of individual members, or that are located on sites having unusual topographical, geological, or climatic conditions might not be adequately covered. In such cases, appropriate engineering principles providing a level of reliability at least equivalent to that provided by this Standard should be applied.

1.4 Dynamic effects of wind
This Standard does not contain mandatory requirements that take into account the dynamic effects of wind.

1.5 Other design approaches
A rational design based on theory, analysis, and engineering practice, acceptable to the owner and regulatory authority, may be used in lieu of the design procedures or materials described in this Standard. In such cases, the design should be prepared by an engineer qualified in the specific method and knowledgeable about the materials to be used, and should provide a level of safety and performance that is not less than that implicit in this Standard.

1.6 Local, provincial, and federal regulations
Responsibility for observing all applicable local, provincial, and federal regulations is not relieved by compliance with this Standard.

1.7 Terminology
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

See more

Also Bought By Customers

  • 1776207

    CSA S408-11
    Priced From $113.00

  • 2901323

    CSA S16:24
    Priced From $250.00

  • 2908930

    CSA O86:24
    Priced From $250.00

  • 1880989

    CSA S832-14 (R2024)
    Priced From $180.00

 

Document History

  1. CAN/CSA S37:24

    February 2024
    Antennas, Towers, and Antenna-Supporting Structures

    • Most Recent  Most Recent
  2. CAN/CSA S37-18

    October 2018
    Antennas, Towers, and Antenna-Supporting Structures, Includes Update No. 1 (2019) and Errata (2020)

    • Historical Version
  3. CSA S37-13

    You are currently viewing this product 👀 currently
    viewing

    November 2013
    Antennas, Towers, and Antenna-Supporting Structures

    • Historical Version
  4. CSA S37-01 (R2011)

    October 2001
    Antennas, Towers, and Antenna-Supporting Structures

    • Historical Version

Browse related products from CSA Group

  • CSA Group > Construction and Engineering > Structures

Order Options

Delivery Options
Price: $125.00
Available for Immediate Download

Product Details

Edition:

7th

Published:

11/01/2013

ISBN(s):

9781771390224

Number of Pages:

221

File Size:

1 file

Product Code(s):

2422031, 2422031

Note:

This product is restricted and cannot be purchased in the following countries Russia, Ukraine, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-s37-13?product_id=1869686
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463804088
Order #: None
Cookies: YES
×