accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA W48-14

CSA W48-14 Historical [ Withdrawn ]

1873290  Preview

Filler metals and allied materials for metal arc welding

standard by CSA Group , 01/01/2014

This document has been replaced. View the most recent version.
This item is not available for sale.

Track This

Full Description

<

Preface

This is the third edition of CSA W48, Filler metals and allied materials for metal arc welding. It supersedes the previous edition, published in 2006.

Scope

1.1
This Standard specifies requirements for the classification and certification of

a) carbon steel covered electrodes for shielded metal arc welding (SMAW);

b) chromium and chromium-nickel steel covered electrodes for SMAW, including electrodes designated for welding heat-resistant steels containing more than 11% chromium and less than 50% nickel;

c) low alloy steel covered electrodes for SMAW;

d) wire electrodes, rods and deposits for gas-shielded arc welding (GMAW, GTAW, and PAW) of nonalloy and fine-grained steels, as specified in Clause 1.2;

e) carbon steel electrodes for flux-cored arc welding (FCAW) and metal-cored arc welding (MCAW) as specified in Clause 1.3;

f) fluxes and solid carbon steel electrodes for submerged arc welding (SAW); and

g) fluxes and composite carbon steel electrodes for SAW.

1.2
Wire electrodes and deposits for GMAW of non-alloy and fine-grained steels are classified and certified under this Standard using the designations and classification requirements specified in CAN/CSA-ISO 14341. The procedures and conditions for required tests, including radiographic test requirements, are specified in Clause 7.

1.3
Wire electrodes and deposits for carbon and low alloy steel FCAW and MCAW electrodes are classified and certified under this Standard using the designations and classification requirements specified in AWS A5.36/A5.36M, and the requirements of Annex N of this Standard. Package marking is specified in Clause 8.1.

1.4
The filler metals and allied materials covered by this Standard are classified in accordance with requirements based on one or more of the following criteria:

a) chemical composition;

b) usability characteristics;

c) type of covering (for covered electrodes);

d) diffusible hydrogen in weld metal (hydrogen-controlled classifications);

e) mechanical properties of weld metal (including heat treatment condition); and

f) positions of welding for which electrodes are suitable.

The clause and table references for the classification requirements for each consumable type are specified in Clause 1.1.

These requirements are not intended to preclude the use of electrodes and/or fluxes classified in this Standard with any other process or any other shielding gas, combination of shielding gases, or flux for which they are found suitable.

1.5
This Standard does not allow an electrode certified under one classification to be certified under another classification for the same welding process, with the following exceptions (until the end of 2015 when AWS A5.36/A5.36M comes into full force):

a) For SAW:

   i) A composite electrode may be certified under different classifications in combination with different fluxes.

   ii) Fluxes may be classified under any number of classifications, for weld metal in either or both of the as-welded and post-weld heat-treated conditions, or using different electrode classifications.

b) For FCAW and MCAW:

   i) E49XT-12 may also be listed as E49XT-9 and E49XT-1.

   ii) E49XT-9 may also be listed as E49XT-1.

   iii) E491X-X (or E431X-X) may also be listed as E490X-X (or E430X-X) for sizes too large for allposition welding.

   iv) E49XC-6 may also be listed as E49XC-3.

   v) E49XT-12M may also be listed as E49XT-9M and E49XT-1M.

   vi) E49XT-9M may also be listed as E49XT-1M.

   vii) E49XT-X may also be listed as E49XT-XM, or vice versa, provided that the electrode meets the requirements of both of these classifications.

c) For chromium and chromium-nickel steel covered electrodes, materials classified under one classification may be classified under any other classification of this Standard provided that they meet all of the requirements for those classifications, except that a material may not be classified under more than one of the following: EXXX-15, EXXX-16, EXXX-17, or EXXX-26 designations.

d) For wire electrodes and deposits for GMAW of non-alloy and fine-grained steel, materials classified under one classification on the "A" side may be classified under another classification on the "B" side, and vice versa, as allowed by CAN/CSA-ISO 14341.

1.6
For purposes of determining compliance with the requirements of this Standard, the actual test values obtained are to be subjected to the rounding off rules of ISO 80000-1:2009, Clause B.3, Rule A. If the measured values are obtained by equipment calibrated in units other than those of this Standard, the measured values shall be converted to the units of this Standard before rounding. If an arithmetic average value is to be compared to the requirements of this Standard, rounding is to be done only after calculating the arithmetic average. If a test method cited in this Standard contains instructions for rounding that conflict with the instructions of this Standard, the rounding requirements of the test method will apply. The rounded results will fulfil the requirements of the appropriate table for the classification under test.

1.7
This Standard does not address safety associated with welding and welding practices.

Note: CSA W117.2 addresses safety in welding and should be followed in addition to applicable workplace health and safety legislation. It is the responsibility of the users of this Standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.8
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

1.9
The values given in SI (metric) units are the standard. Yard/pound (imperial) units are provided in Annex L for information only.

See more

Also Bought By Customers

  • 2902023

    CSA W59.2:24
    Priced From $158.00

  • 2945636

    CSA W47.1:25
    Priced From $240.00

  • 2940096

    CSA W117.2:25
    Priced From $110.00

  • 1862723

    CSA G40.20-13/G40.21-13 (R2023)
    Priced From $178.00

 

Document History

  1. CSA W48:23

    February 2023
    Filler metals and allied materials for metal arc welding, Includes Errata (2025)

    • Most Recent  Most Recent
  2. CSA W48-18

    January 2018
    Filler metals and allied materials for metal arc welding

    • Historical Version
  3. CSA W48-14

    You are currently viewing this product 👀 currently
    viewing

    January 2014
    Filler metals and allied materials for metal arc welding

    • Historical Version
  4. CSA W48-06 (R2011)

    April 2006
    Filler metals and allied materials for metal arc welding

    • Historical Version
  5. CAN/CSA W48-01

    October 2001
    Filler Metals and Allied Materials for Metal Arc Welding (Developed in cooperation with the Canadian Welding Bureau)

    • Historical Version

Browse related products from CSA Group

  • CSA Group > Construction and Engineering > Welding and Structural Metals

Order Options

Unavailable

Product Details

Edition:

3rd

Published:

01/01/2014

ISBN(s):

9781771392969

Number of Pages:

133
✕

Document Delivery Options

✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-w48-14?product_id=1873290
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463798241
Order #: None
Cookies: NO
×