accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA Z314.8-14

CSA Z314.8-14 Historical [ Withdrawn ]

1874382

Decontamination of Reusable Medical Devices

standard by CSA Group , 02/01/2014

This document has been replaced. View the most recent version.
This item is not available for sale.

Track This

Full Description

Preface

This is the fourth edition of CSA Z314.8 Decontamination of reusable medical devices. It supersedes the previous editions published in 2008, 2000, and 1998. It is one of a series of CSA Standards dealing with the safe and effective sterilization of medical supplies and equipment.

This new edition provides users with an expanded section on endoscopy, including a table providing guidance on timely reprocessing. Requirements explained in terms of A0 values are also introduced.

This Standard is to be used in conjunction with CSA Z314.0, Medical device reprocessing - General requirements, which provides the framework to establish, document, and maintain policies and procedures for the reprocessing of medical devices to develop a Quality Management System (QMS).

Scope

1.1
This Standard describes essential elements and methods in the safe handling, transportation, and biological decontamination of contaminated reusable medical devices and is to be used in conjunction with CSA Z314.0. Where differences exist, the requirements of this Standard apply.

Note: The biological decontamination process includes thorough cleaning and, whenever necessary for personnel or patient safety, appropriate application of a disinfection or sterilization process.

1.2
This Standard includes requirements for

a) decontamination areas and equipment;

b) immediate handling of contaminated medical devices at the point of use;

c) transport of contaminated medical devices; and

d) decontamination policies and procedures (in general, as related to reusable diagnostic and therapeutic medical devices, and specifically, as related to reusable respiratory/anaesthesia devices, flexible fibre optic endoscopes, ultrasound transducer probes, and electronic patient-applied devices).

Notes:

1) More detailed procedures can be required for specific medical devices or applications.

2) See Figure 1 for an overview of the medical device reprocessing steps specified in this Standard.

1.3
This Standard does not apply to

a) the terminal sterilization of reusable medical devices;

Note: See CSA Z314.0, CSA Z314.3, CSA Z314.23, and CAN/CSA-ISO 14937.

b) single-use/disposable medical device reprocessing;

Note: Information concerning safety, technology, cost/benefit, and legal issues involving the reuse of single use/disposable devices is found in publications such as Canadian Healthcare Association (1996) and Emergency Care Research Institute (1997).

c) medical devices that have been used with patients who are known or suspected to have Creutzfeldt-Jakob disease or prion-related diseases; and

Note: See Public Health Agency of Canada's Variant Creutzfeld-Jakob Disease (vCJD) and Infection Control Guidelines: Classic Creutzfeldt-Jakob Disease in Canada: Quick Reference Guide.

d) the reprocessing and reuse of haemodialyzers.

Note: See CAN/CSA-Z364.1.3.

1.4
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

See more

Also Bought By Customers

  • 2523475

    CAN/CSA Z314:23
    Priced From $605.00

  • 944796

    CAN/CSA Z17665-1-09 (R2023)
    Priced From $178.00

  • 1502605

    CAN/CSA Z11137-1-07 (R2021)
    Priced From $176.00

  • 1649566

    CAN/CSA Z15883-1-09 (R2023)
    Priced From $210.00

 

Document History

  1. CAN/CSA Z314:23

    January 2023
    Canadian medical device reprocessing in all health care settings, Includes Update No. 1 (2024)

    • Most Recent  Most Recent
  2. CAN/CSA Z314-18

    February 2018
    Canadian medical device reprocessing

    • Historical Version
  3. CSA Z314.23-16

    April 2016
    Chemical sterilization of reusable medical devices in health care settings

    • Historical Version
  4. CSA Z314.22-16

    February 2016
    Management of loaned, reusable medical devices

    • Historical Version
  5. CSA Z314.10.2-15

    August 2015
    Laundering, maintenance, and preparation of reusable gowns, drapes, and wrappers for health care settings and laundries

    • Historical Version
  6. CSA Z314.10.1-15

    August 2015
    Selection and use of gowns and drapes intended for use in health care facilities

    • Historical Version
  7. CSA Z314.15-15

    August 2015
    Storage, transportation, and distribution of single use and reusable medical devices

    • Historical Version
  8. CSA Z314.14-15

    August 2015
    Selection and use of packaging (sterile barrier systems) in healthcare settings

    • Historical Version
  9. CSA Z314.3-14

    August 2014
    Effective sterilization in health care settings by the steam process

    • Historical Version
  10. CSA Z314.8-14

    You are currently viewing this product 👀 currently
    viewing

    February 2014
    Decontamination of Reusable Medical Devices

    • Historical Version
  11. CSA Z314.0-13

    March 2013
    Medical device reprosessing - General requirements

    • Historical Version
  12. CSA Z314.23-12

    March 2012
    Chemical sterilization of reusable medical devices in health care facilities

    • Historical Version
  13. CSA Z314.22-10 (R2015)

    October 2010
    Management of loaned, reusable medical devices, Includes Update No. 1 (2011)

    • Historical Version
  14. CSA Z314.14-10 (R2015)

    May 2010
    Selection and Use of Rigid Sterilization Containers

    • Historical Version
  15. CAN/CSA Z314.10.2-10 (R2015)

    February 2010
    Laundering, maintenance, and preparation of multiple-use gowns, drapes, and wrappers in health care facilities

    • Historical Version
  16. CAN/CSA Z314.10.1-10 (R2015)

    February 2010
    Selection and use of gowns, drapes, and wrappers in health care facilities

    • Historical Version
  17. CAN/CSA Z314.15-10 (R2015)

    February 2010
    Warehousing, storage, and transportation of clean and sterile medical devices

    • Historical Version
  18. CSA Z314.3-09 (R2014)

    March 2009
    Effective sterilization in health care facilities by the steam process

    • Historical Version
  19. CAN/CSA Z314.8-08 (R2013)

    March 2008
    Decontamination of Reusable Medical Devices

    • Historical Version
  20. CAN/CSA Z314.14-04

    July 2005
    Selection and Use of Rigid Sterilization Containers

    • Historical Version
  21. CAN/CSA Z314.22-04

    July 2004
    Management of Loaned, Shared, and Leased Medical Devices, Includes Update No. 1 (2006)

    • Historical Version
  22. CAN/CSA Z314.15-03 (R2008)

    June 2003
    Warehousing, Storage, and Transportation of Clean and Sterile Medical Devices

    • Historical Version
  23. CAN/CSA Z314.10-03 (R2008)

    April 2003
    Selection, Use, Maintenance, and Laundering of Reusable Textile Wrappers, Surgical Gowns, and Drapes for Health Care Facilities

    • Historical Version
  24. CAN/CSA Z314.3-01 (R2006)

    January 2001
    Effective Sterilization in Health Care Facilities by the Steam Process

    • Historical Version
  25. CAN/CSA Z314.8-00 (R2005)

    June 2000
    Decontamination of Reusable Medical Devices

    • Historical Version
  26. CAN/CSA Z314.10-97

    March 2000
    Selection, Use, Maintenance and Laundering of Reusable Textile Wrappers, Surgical Gowns and Drapes for Health Facilities

    • Historical Version
  27. CSA Z314.14-93 (R1999)

    December 1999
    Selection and Use of Rigid Sterilization Containers

    • Historical Version
  28. CAN/CSA Z314.3-M91

    January 1991
    Effective Sterilization in Hospitals by the Steam Process

    • Historical Version

Browse related products from CSA Group

  • CSA Group > Health Care and Medical Devices > Sterilization

Order Options

Unavailable

Product Details

Edition:

4th

Published:

02/01/2014

Number of Pages:

97
✕

Document Delivery Options

✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-z314-8-14?product_id=1874382
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463806978
Order #: None
Cookies: YES
×