accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. DE-13-038 -- A Novel Building Component Hybrid Vacuum Glazing - A Modeling and Experimental Validation

DE-13-038 -- A Novel Building Component Hybrid Vacuum Glazing - A Modeling and Experimental Validation ✓ Most Recent

1867127

Conference Proceeding by ASHRAE , 2013

Yueping Fang, PhD; Trevor J. Hyde, PhD; Farid Arya; Neil Hewitt, PhD

Track This

Full Description

The thermal performance of a hybrid vacuum glazing (HVG) was simulated using a finite volume model (FVM) and theoretically analysed using an analytic model. HVG is the combination of a conventional double vacuum glazing (DVG) and a third glass sheet separated by a gas-filled cavity. The DVGintegrated within theHVGcomprises two 4mm(0.16 in.) thick glass sheets both coated with a low-emittance (low-e) coating with emittance of 0.16, sealed around their periphery by a 6 mm (0.24 in.) wide indium based sealant and separated by an array of stainless steel support pillars with a diameter of 0.4 mm (0.02 in.), a height of 0.2 mm (0.01 in.), and spaced at 25mm(0.98 in.) within the vacuum gap.TheDVGwas fabricated using the pump-out method and subsequently integrated within the HVG. No low-e coating was employed on the third glass sheet. To validate the simulation results, the thermal performance of both the DVG and HVG were analyzed using a guarded hot box calorimeter (GHBC) constructed in accordance with the requirements of ISO 8990 (ISO 1996).

The simulation results showed that for the 0.4 by 0.4m(1.31 by 1.31 ft) HVG with the configuration parameters listed above, the thermal transmission U-value at the centre-of-glazing area was 0.64 W·m-2·K-1 (0.11 Btu·h-1·ft-2·°F). Before integration with the third glass sheet, the U-value of the centre-of-glazing area of the DVG was 0.85 W·m-2·K-1 (0.15 Btu·h-1·ft-2·°F). The U-valueof theHVGcalculated usingthe analyticmodelwas0.63 W·m-2·K-1 (0.11 Btu·h-1·ft-2·°F,) which was in good agreement with that predicted using the FVM with a deviation of less than 1.5%. Using the GHBC, the experimentally determined U-value at the centre-of-glazing area of the HVG was 0.66 W·m-2·K-1 (0.12 Btu·h-1·ft-2·°F) which was in very good agreement with the prediction by the FVM with a deviation of 3.1%. The thermal performance of the HVG compares favorably with conventional three-pane insulating glazing systems and offers significant potential as an energy saving building component.

See more

Also Bought By Customers

  • 1867120

    DE-13-007 -- Thermal Energy Storage for Emergency Cooling...
    Priced From $16.00

  • 1867123

    DE-13-034 -- Assessing the Causes of Combustion Drien Osc...
    Priced From $16.00

  • 1867124

    DE-13-030 -- CFD Analysis of Pressure Losses in Flat-Oval...
    Priced From $16.00

  • 1867160

    DE-13-013 -- An Integrated Fire Safety Plan to Manage Smo...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2013 Annual Conference, Denver, CO > Transactions 2013, Vol. 119, pt. 2 > Technical Papers
  • ASHRAE > Transactions > Transactions 2013, Vol. 119, pt. 2 > Technical Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2013

Number of Pages:

12

File Size:

1 file

Product Code(s):

D-DE-13-038

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/de-13-038-a-novel-building-component-hybrid-vacuum-glazing-a-modeling-and-experimental-validation?product_id=1867127
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463804798
Order #: None
Cookies: YES
×