accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. DE-13-C001 -- Accounting for Exposure Duration in Overheating Risk Assessment - A Chicago Retrofit Case Study

DE-13-C001 -- Accounting for Exposure Duration in Overheating Risk Assessment - A Chicago Retrofit Case Study ✓ Most Recent

1865998

Conference Proceeding by ASHRAE , 2013

W. Victoria Lee; Koen Steemers, PhD RIBA

Track This

Full Description

Increasing occurrences of record high temperatures, hot spells, and deadly heat waves in recent years have warranted a growing global concern with overheating in buildings. This paper demonstrates how two proposed measurements designed to quantify overheating exposure duration, an important aspect of thermal health that has not been addressed by the existing overheating risk assessment approaches, can be used to inform the selection of retrofitting options in places with continental climates such as Chicago where both the cooling and heating seasons are challenging. The two measurements -- consecutive hours of exceedance (CHE) and cumulative degree exceedance of continuous exposure (CDECE), allow an assessment based on continuously overheated intervals (COI) that more appropriately capture the state of overheating as relevant to the occupants' thermal health than does aggregated assessment which is easily influenced by how thresholds and occupancy schedule are defined. In the context of a typical pre-1942 single-story uninsulated timber-frame Chicago bungalow, as simulated in this study, although wall insulation is found to be more effective than roof insulation in the winter, there is little difference in the overheating risk reduction potential of the two in the summer. However, when wall insulation is applied in tandem with roof insulation, thermal performance is improved in both seasons. Further analysis is needed to investigate the energy and cost savings of these upgrades. More broadly, given further epidemiological understanding of heat-related morbidity and mortality, CHE and CDECE may aid in the identification of potentially health-threatening building stocks within a city or region, and in the selection of appropriate retrofitting options to reduce heat-related health risks in buildings.

See more

Also Bought By Customers

  • 1865993

    DE-13-C077 -- Measurement and Verification Study in Korea
    Priced From $16.00

  • 1866004

    DE-13-C037 -- Modeling Advanced Heat Pump Water Heater Sy...
    Priced From $16.00

  • 1866008

    DE-13-C005 -- Evaluation of A Climate Modeling Procedure ...
    Priced From $16.00

  • 1866044

    DE-13-C030 -- Understanding Building Infrastructure and B...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2013 Annual Conference, Denver, CO > Conference Papers > Conference Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2013

Number of Pages:

8

File Size:

1 file

Product Code(s):

D-DE-13-C001

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/de-13-c001-accounting-for-exposure-duration-in-overheating-risk-assessment-a-chicago-retrofit-case-study?product_id=1865998
Referrer: Direct Navigation
IP: 216.73.216.4
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463691021
Order #: None
Cookies: YES
×