accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. DE-79-05-5 -- Thermal Performance of Insulating Window Systems

DE-79-05-5 -- Thermal Performance of Insulating Window Systems ✓ Most Recent

1853364

Conference Proceeding by ASHRAE , 1979

Stephen E. Selkowitz, Associate Member ASHRAE

Track This

Full Description

Energy efficient windows coupled with winduw management strategies can alter the role of windows from that of an energy drain toa net supplier of energy to the building. This will require effective utilization of winter solar gain and daylight, coupled with reductions in thermal. losses. Thermal losses of conventional double glazing are less than those of single glass but fall far short of the lower loss rate of other building elements. This paper reviews several improvements in window design, which show promise of reducing the window Uvalue to as low as .5 W/m.K (.1Btu/hr.ft2.oF). These include the use of: convection suppression in double glazed windows using low conductivity fill gases, with vertical and horizontal partitions; partial evacuation of the air space; transparent heat mirror coatings on glass and on plastic interlayers; movable insulating devices; and air flow windows. Thermal comfort, cost effectiveness and other non-energy related performance issues are discussed briefly relativeto several of the proposed designs.

See more

Also Bought By Customers

  • 1853243

    DE-79-01-3 -- Effect of Fluctuating Wind Pressures on Nat...
    Priced From $16.00

  • 1853317

    DE-79-06-4 -- High Air Volume Solar Collection Wall on Me...
    Priced From $16.00

  • 1853341

    DE-79-08-3 -- Dynamic Test Results of an Absorption Chill...
    Priced From $16.00

  • 1853371

    DE-79-04-1 -- Energy Storage Augmented by Solar Energy
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 1979 Annual Conference, Detroit, MI > Transactions 1979, Vol. 85, pt. 2 > Symposium Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

1979

Number of Pages:

17

File Size:

1 file

Product Code(s):

D-DE-79-05-5

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/de-79-05-5-thermal-performance-of-insulating-window-systems?product_id=1853364
Referrer: Direct Navigation
IP: 216.73.216.61
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463810494
Order #: None
Cookies: YES
×