accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. IEEE 1050-1996

IEEE 1050-1996 Historical

1777898

IEEE Guide for Instrumentation and Control Equipment Grounding in Generating Stations

standard by IEEE , 09/17/1996

This document has been replaced. View the most recent version.

Track This

Full Description

Scope

This application guide was developed to identify instrumentation and control (I&C) equipment grounding methods to achieve both a suitable level of protection for personnel and equipment, and to provide suitable electric noise immunity for signal ground references in generating stations. Both ideal theoretical methods and accepted practices in the electric utility industry are presented. Special applications relating to advanced energy storage and conversion technologies (photovoltaics, fuel cells, etc.) have not been considered. This guide is intended to provide information about grounding methods for generating station I&C equipment. Grounding design is normally based on the concept of two separate grounding systems the equipment ground and the signal reference ground. The grounding of instrument chassis, racks, cable sheaths, or cable shields and signal pairs requires special care to ensure that personnel working on equipment are adequately protected against electrical shock hazards during both normal and abnormal conditions, as well as to ensure that interference signals are not inadvertently coupled into signal circuits. The basic theory and guidelines to be understood before designing I&C grounding are presented in clause . Clause provides guidance for grounding of equipment associated with generating station I&C systems and presents various approaches to providing a signal ground system. Clause presents accepted practices in grounding the shields of I&C cables, while clause covers the testing of I&C grounding systems.

Purpose

The typical environment in a generating station provides many sources of electrical noise, such as the switching of large inductive loads, high fault currents, static switching, and high-energy, high-frequency transients associated with switching at the generator or transmission voltage level. The increasing use of solid-state equipment, computer- or microprocessor-based control, and signal multiplexing systems in these applications introduces a number of specific concerns with respect to electrical noise control. This guide discusses methods for the grounding of instrumentation and control equipment and their associated circuits in generating stations. It is intended to provide guidance for the design of grounding systems for instrumentation and control equipment specific to the generating station. The low-level electrical signals transmitted from various instrumentation and control equipment in a generating station through long cables may undergo signal distortion as they travel to the receiving end. This distortion is typically caused by noise pickup either at the signal source or along the cable run. The level of noise on the received signal can cause errors in measurement and control functions (and in extreme cases, damage to equipment), which in turn may result in costly unit downtime. The use of proper grounding along with proper shielding techniques can solve a large percentage of noise problems. It should be recognized that there are numerous accepted grounding techniques and that the actual installation of a ground system should be made in consultation with instrumentation and control equipment manufacturers. The grounding methods in this guide are intended to minimize degradation of instrumentation and control signals in generating stations. By contrast, the station grounding system is mainly oriented toward meeting the requirements of various safety codes that aim to establish a grounding system that will provide a low-impedance path to ground. This low-impedance path helps to ensure that high voltages are not developed on equipment or structures as a consequence of lightning surges, electrical faults, circulating currents, or static charges. This guide is complementary to IEEE Std 665-1995 .

Abstract

Revision Standard - Superseded. Information about grounding methods for generating station instrumentation and control (I&C) equipment is provided. The identification of I&C equipment methods to achieve both a suitable level of protection for personnel and equipment is included, as well as suitable noise immunity for signal ground references in generating stations. Both ideal theoretical methods and accepted practices in the electric utility industry are presented. See more

Also Bought By Customers

  • 1777695

    IEEE 142-2007
    Priced From $196.00

  • 7381

    IEEE 518-1982
    Priced From $168.00

  • 26327

    IEEE 665-1995
    Priced From $136.00

  • 1890140

    IEEE C57.13.3-2014
    Priced From $113.00

 

Document History

  1. IEEE 1050-2004

    September 2005
    IEEE Guide for Instrumentation and Control Equipment Grounding in Generating Stations

    • Most Recent  Most Recent
  2. IEEE 1050-1996

    You are currently viewing this product 👀 currently
    viewing

    September 1996
    IEEE Guide for Instrumentation and Control Equipment Grounding in Generating Stations

    • Historical Version
  3. IEEE 1050-1989

    September 1989
    IEEE Guide for Instrumentation and Control Equipment Grounding in Generating Stations

    • Historical Version

Browse related products from IEEE

  • IEEE > By Technical Committee > Power and Energy > Power Generation
  • IEEE > By ICS Code > 27.000: Energy and heat transfer engineering > 27.100: Power stations in general

Order Options

Delivery Options
Price: $147.00
Available for Immediate Download

Product Details

Published:

09/17/1996

ISBN(s):

9780738111070

Number of Pages:

100

File Size:

1 file

Product Code(s):

STDSU94417

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/ieee-1050-1996?product_id=1777898
Referrer: Direct Navigation
IP: 216.73.216.127
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463748117
Order #: None
Cookies: NO
×