accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. IEEE 1243-1997

IEEE 1243-1997 ✓ Most Recent

42216

IEEE Guide for Improving the Lightning Performance of Transmission Lines

standard by IEEE , 12/16/1997

Normative References
Track This
👥 Multi-User PDF
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

Scope

For this guide, a transmission line is any overhead line with a phase-to-phase voltage exceeding 69 kV and an average conductor height of more than 10 m. The transmission line is usually shielded by one or more overhead ground wires (OHGWs), at least for a short distance from a substation. While reference is primarily made to ac transmission characteristics, the guide is also relevant for high-voltage direct-current (HVDC) overhead lines. The guide is written for the transmission-line designer. When given the problem of designing or redesigning a transmission line, the designer should consider certain limiting factors such as the voltage level, the beginning and ending points for the transmission line, and the desired ampacity of the line. Sometimes the exact route, and the type of conductor and structure have already been determined. Usually the designer may choose structural details, the geometry of the structure, the structure height, the exact placement of the OHGWs, the amount and type of insulation, the type of grounding, and other design features of a line. This guide is written to show the designer which choices will improve or degrade lightning performance. Sections of the guide discuss the effect of routing, structure type, insulation, shielding, and grounding. An additional section discusses several special methods, which may be used to improve lightning performance. Finally, in Annex B, a listing and description of the FLASH program is presented. The line designer should be aware that lightning performance is not of primary importance in the economics of line designing. Other factors, such as line length, right-of-way costs, construction costs, material costs, and losses affect the economics of a line design much more than lightning performance. The designer should always balance the costs of higher insulation levels, improved grounding, better shielding, or line relocation against the benefits of improved reliability.

Purpose

This guide contains simple mathematical equations, tables, and graphs that provide the information needed to design an overhead power transmission line with minimum lightning interruptions. Versions 1.6 and 1.7 of the FLASH program are provided on the diskette included with this guide. Annex B includes a description of the program. The FLASH program uses the models in the design guide along with a description of transmission line features to estimate the lightning outage rate that may be expected. These simplified models may also be adapted to assess the benefits of novel methods for improving lightning performance.

Abstract

New IEEE Standard - Inactive-Reserved. The effects of routing, structure type, insulation, shielding, and grounding on transmission lines are discussed. The way these transmission-line choices will improve or degrade lightning performance is also provided. An additional section discusses several special methods that may be used to improve lightning performance. Finally, a listing and description of the FLASH program is presented.
See more

Also Bought By Customers

Also Bought By Customers…

 

Normative References

Normative References…

See all references

Browse related products from IEEE

  • IEEE > By Technical Committee > Power and Energy > Power Transmission and Distribution
  • IEEE > By ICS Code > 29.000: Electrical engineering > 29.020: Electrical engineering in general
  • IEEE > By ICS Code > 29.000: Electrical engineering > 29.240: Power transmission and distribution networks > 29.240.20: Power transmission and distribution lines

Order Options

Delivery Options
Price: $156.00
Available for Immediate Download

Product Details

Published:

12/16/1997

ISBN(s):

0738103829

Number of Pages:

26

File Size:

1 file , 600 KB

Product Code(s):

STDRES94542

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

Self Extracting File Format (SEFF)
SEFF files are downloadable documents that are not in PDF format. The most common SEFF files will be ZIP files, or downloadable Excel tables.
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Normative References

A normative reference is a mandatory external document or standard that you must read, use, and follow to fully apply or comply with the main standard or technical specification you are reading. Without it, you cannot correctly understand or implement the rules of the primary document.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/ieee-1243-1997?product_id=42216
Referrer: Direct Navigation
IP: 216.73.216.137
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1464098902
Order #: None
Cookies: YES
×