accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. IEEE 1627-2019

IEEE 1627-2019 ✓ Most Recent

2003158  Preview

IEEE Standard for Transient Overvoltage Protection of DC Electrification Systems by Application of DC Surge Arresters

standard by IEEE , 07/29/2019

Normative References
Track This
👥 Multi-User PDF
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

Scope

This standard covers the application of dc surge arresters for transient overvoltage protection of dc transit electrification systems. These dc transit electrification systems include light rail, heavy rail, streetcar, and trolley bus systems. This standard covers the selection and application of metal-oxide varistor (MOV) gapless-surge arresters to divert surge energy away from the transit system components. It does not cover low-voltage SPDs that are required within dc traction power system equipment, such as rectifier units, vehicle propulsion systems, or other sensitive components of the dc transit system.

Purpose

It is the purpose of this standard to provide uniform practices for lightning and switching transient overvoltage protection of dc transit electrification by proper selection of dc surge arresters based on the surge environment and site conditions of the transit system. This standard allows the use of SPDs in dc transit systems to avoid insulation failure due to transient overvoltage. Transient overvoltage protection is just as important as short- circuit protection. This standard will minimize equipment damage caused by transient overvoltages, increasing system reliability that will result in reduced maintenance.

Abstract

New IEEE Standard - Active. The design and application of dc surge arresters to protect dc electrification system from transient overvoltage caused by lightning and switching surges is the purpose of this standard. Lightning surges can cause high energy transient overvoltages by direct or indirect coupling with a dc electrification system. Transient overvoltage protection from lightning and switching surges of various dc transit electrification systems can be achieved by the application of metal-oxide varistor (MOV) gapless-surge arresters. The application of surge arresters to running rails in areas where lightning activity is severe requires special study of protection coordination with rail-ground shorting devices [also called voltage-limiting devices (VLDs)] and review of track circuits applied at the transit system. Such study and criteria of selecting VLDs is not included in this standard. However, a surge arrester applied to running rails in higher keraunic areas has been included and requires coordination with both the VLD devices and track circuits applied in the transit system. Many modern light- and heavy-rail transit projects use VLDs, although their application can be avoided by implementing other design measures, such as insulated platforms, or by simply coating the vehicle surface with some special insulation. The purpose of installing VLDs at dc transit projects is to enhance the safety of personnel from the touch potential (rail-ground voltage) on the train vehicle surface. No industry standard on VLDs exists today in North America. Only IEC EN 50526-2 covers VLD.
See more

Also Bought By Customers

Also Bought By Customers…

 

Normative References

Normative References…

Browse related products from IEEE

  • IEEE > By Technical Committee > Application Areas > Vehicular/Transportation Technology
  • IEEE > By ICS Code > 29.000: Electrical engineering > 29.120: Electrical accessories > 29.120.50: Fuses and other overcurrent protection devices
  • IEEE > By ICS Code > 29.000: Electrical engineering > 29.280: Electric traction equipment

Order Options

Delivery Options
Price: $69.00
Available for Immediate Download

Product Details

Published:

07/29/2019

ISBN(s):

9781504458849, 9781504460385, 9781504458856

Number of Pages:

50

File Size:

1 file , 1.6 MB

Product Code(s):

STD23718, STDPD23718, STDPL23718

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
Printed Edition + PDF
A combination of a Hard Copy product that is mailed and an electronic product such as a PDF or SPDF (Secure PDF). Refer to Help Center for more details.
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Normative References

A normative reference is a mandatory external document or standard that you must read, use, and follow to fully apply or comply with the main standard or technical specification you are reading. Without it, you cannot correctly understand or implement the rules of the primary document.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/ieee-1627-2019?product_id=2003158
Referrer: Direct Navigation
IP: 216.73.216.137
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1464098477
Order #: None
Cookies: NO
×