accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. IES RP-27.1-15

IES RP-27.1-15 Historical

1912795  Preview

Photobiological Safety for Lamps and Lamp Systems - General Requirements

standard by Illuminating Engineering Society , 11/06/2015

This document has been replaced. View the most recent version.
This item is not available for sale.
Track This
👥 Multi-User PDF
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

To evaluate a broad-band optical source, such as an arc lamp, an incandescent lamp, a fluorescent lamp, an array of lamps or a lamp system, it first is necessary to determine the spectral distribution of optical radiation emitted from the source at the point or points of nearest human access. This accessible emission spectral distribution of interest for a lighting system may differ from that actually being emitted by the lamp alone due to the filtration by any optical elements (e.g., projection optics) in the light path. Secondly, the size, or projected size, of the source should be characterized in the retinal hazard spectral region. Thirdly, it may be necessary to determine the variation of irradiance and projected radiance (see the Glossary) with distance. The performance of the necessary measurements is not an easy task without sophisticated instruments. Users should normally rely upon the expertise of manufacturers for information on lamps and lamp systems. Safety requirements and reference measurement techniques for lamps and specific lamp systems are provided in later standards of this series (i.e., ANSI/IES RP-27.2-00/R2010 Recommended Practice for Photobiological Safety for Lamps and Lamp Systems - Measurement Techniques and ANSI/IES RP-27.3-07 Recommended Practice for Photobiological Safety for Lamps - Risk Group Classification Labeling). Finally, there are well known optical radiation hazards associated with some lamps and lamp systems.

The purpose of these standards is to inform the public and original equipment manufacturers (OEMs) about potential radiation hazards that may be associated with various lamps and lamp systems. It is also the purpose of these standards to provide guidance, advice, and standard methods for evaluating and informing the user, both the public and the OEM, about the potential optical radiation hazards that may be associated with these products.

This Recommended Practice covers the evaluation and control of optical radiation hazards from all electrically powered sources of optical radiation that emit in the wavelength range from 200 nm through 3,000 nm (3.0 um [micrometers]) except for light emitting diodes (LEDs) used in optical fiber communication systems and for lasers which are covered in a separate series of ANSI (American National Standards Institute) standards (Series Z136). Federal mandatory requirements for lamps subject to specific Federal Regulations take precedence over requirements in subsequent standards included in this series.

Note 1: Units of wavelength in this document are exclusively in nanometers (nm).

Note 2: Subtended angles are denoted by the full included angle, not the half angle. See more

Also Bought By Customers

Also Bought By Customers…

 

Document History

  1. IES RP-27.1-22

    October 2022
    Recommended Practice: Risk Group Classification and Minimization of Photobiological Hazards from Ultraviolet Lamps and Lamp Systems

    • Most Recent  Most Recent
  2. IES RP-27-20

    April 2020
    Recommended Practice: Photobiological Safety for Lighting Systems

    • Historical Version
  3. IES RP-27.3-17

    January 2017
    Photobiological Safety for Lamps and Lamp Systems - Risk Group Classification and Labeling

    • Historical Version
  4. IES RP-27.1-15

    You are currently viewing this product 👀 currently
    viewing

    November 2015
    Photobiological Safety for Lamps and Lamp Systems - General Requirements

    • Historical Version
  5. IES RP-27.3-07

    May 2007
    Photobiological Safety for Lamps - Risk Group Classification and Labeling

    • Historical Version
  6. IES RP-27.1-05

    October 2005
    Photobiological Safety for Lamps and Lamp Systems - General Requirements

    • Historical Version
  7. IES RP-27.2-00 (R2017)

    May 2000
    Recommended Practice for Photobiological Safety for Lamps and Lamp Systems - Measurement Techniques

    • Historical Version
  8. IES RP-27.1-96

    January 1996
    Photobiological Safety for Lamps and Lamp Systems-General Requirements

    • Historical Version
  9. IES RP-27.3-96

    January 1996
    Photobiological Safety for Lamps - Risk Group Classification and Labeling

    • Historical Version

Browse related products from Illuminating Engineering Society

  • Illuminating Engineering Society > IES Recommended Practices and ANSI Standards

Order Options

Unavailable

Product Details

Published:

11/06/2015

ISBN(s):

9780879953218

ANSI:

ANSI Approved

Number of Pages:

31

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/ies-rp-27-1-15?product_id=1912795
Referrer: Direct Navigation
IP: 216.73.216.241
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1464031422
Order #: None
Cookies: NO
×