accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. LB-17-012 -- Hot-Water Use in Hotels: Part 4--Comparison of Travel and Business Hotel Hot-Water System Monitoring Results

LB-17-012 -- Hot-Water Use in Hotels: Part 4--Comparison of Travel and Business Hotel Hot-Water System Monitoring Results ✓ Most Recent

1993939

Conference Proceeding by ASHRAE , 2017

Carl C. Hiller, PhD, PE, Fellow ASHRAE; Russell Johnson, Member ASHRAE

Track This

Full Description

This paper is based on findings resulting from ASHRAE Research Project RP-1544.

Hot-water use in hotels and its associated energy use is significant. However, information on hotel hot-water use patterns has been limited until now, resulting in most hotel hotwater systems being designed using extremely old hot-water use data (45 to 80 years old) that predate the introduction of water and energy-efficient fixtures and appliances. In recognition of this fact, ASHRAE funded Research Project RP-1544 "Establishing Benchmark Levels and Patterns of Commercial Hot-water Use--Hotels" to both develop a monitoring methodology that could be duplicated by others to collect hot-water use data from a larger number of hotels and to obtain updated hot-water use information from at least two hotels. This paper compares hot-water use results collected for a "travel" hotel that had neither meeting rooms nor food service and a "business" hotel that had both. This paper further discusses how to normalize this information so it is useful for sizing hot-water systems for hotels with differing numbers of guest rooms than those tested. A companion paper released simultaneously with this paper describes how to use this information to select water heating systems for hotels of any desired size, and compares results of this sizing method to other hotel hot-water system sizing methods described in ASHRAE Handbook--HVAC Applications, Chapter 50, Service Water Heating, through the use of examples.

See more

Also Bought By Customers

  • 1993940

    LB-17-017 -- ASHRAE SSPC 170 Natural Ventilation Task Gro...
    Priced From $16.00

  • 1993945

    LB-17-019 -- Energy and Control Performance Investigation...
    Priced From $16.00

  • 1993947

    LB-17-001 -- Autonomous Robotic Building Energy Audits: D...
    Priced From $16.00

  • 1993950

    LB-17-003 -- Development of Maximum Technically Achievabl...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2017 Annual Conference, Long Beach, CA > Transactions 2017, Vol 123 pt. 2 > Technical Papers
  • ASHRAE > Transactions > Transactions 2017, Vol. 123, pt. 2 > Technical Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2017

Number of Pages:

17

Units of Measure:

Dual

File Size:

1 file

Product Code(s):

D-LB-17-012

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/lb-17-012-hot-water-use-in-hotels-part-4-comparison-of-travel-and-business-hotel-hot-water-system-monitoring-results?product_id=1993939
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463804263
Order #: None
Cookies: YES
×