accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. LO-09-020 -- CFD Study of Smoke Movement during the Early Stage of Tunnel Fires: Comparison with Field Tests

LO-09-020 -- CFD Study of Smoke Movement during the Early Stage of Tunnel Fires: Comparison with Field Tests ✓ Most Recent

1714037

Conference Proceeding by ASHRAE , 2009

Yoon J. Ko; George V. Hadjisophocleous, PhD, PE; Ahmed Kashef, PhD, PE

Track This

Full Description

Temperature and smoke spread in the early stage of a fire were modeled, using computational fluid dynamic techniques, and compared with data obtained from field tests conducted in an operating roadway tunnel in the City of Montreal, Canada. Fire characteristics, including temperatures and smoke spread over the tunnel were measured during these tests. Two types of fire scenarios were simulated: gasoline pool fires under vehicles and gasoline pool fires behind vehicles. The estimated fire size used in the simulations was 650 kW. The initial and boundary conditions of each simulation were set to mimic the conditions of the corresponding test. Comparisons were made to temperature and smoke optical density measurements. In general, favourable comparisons between the numerical predictions and the experimental data were observed. The ceiling temperature downstream of the fire decreased with an increase in the distance from the fire source, which is also the case for smoke optical density. The ceiling temperatures produced by the fire behind the vehicle were higher than those produced by the fire under the vehicle. The temperature variation along the central cross section of the tunnel shows that the highest ceiling temperature occurs 3~5 m downstream of the fire because the plume was tilted by the airflow inside the tunnel. Fire location had a significant impact on ceiling temperature development in the tunnel. The airflow conditions at the fire location significantly affect smoke and temperature distributions in the tunnel which will also affect the performance of detection systems.

 

Units: SI 

See more

Also Bought By Customers

  • 1712376

    OR-10-001 -- The Design of Natural Ventilation Systems to...
    Priced From $16.00

  • 1712380

    LO-09-008 -- From EMPD to CFD—Overview of Different Appro...
    Priced From $16.00

  • 1712432

    LO-09-043 -- A Comparative Study of the Effect of Initial...
    Priced From $16.00

  • 1714032

    LO-09-013 -- High Performance Computing with High Efficiency
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2009 Annual Conference, Louisville, KY > Transactions 2009, Vol. 115, pt. 2 > Technical Papers
  • ASHRAE > Transactions > Transactions 2009, Vol. 115, pt. 2 > Technical Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2009

Number of Pages:

9

File Size:

1 file

Product Code(s):

D-LO-09-020

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/lo-09-020-cfd-study-of-smoke-movement-during-the-early-stage-of-tunnel-fires-comparison-with-field-tests?product_id=1714037
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463804694
Order #: None
Cookies: YES
×