accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. MN-00-03-2 -- Effect of Data Period-of-Record on Estimation of HVAC&R Design Temperatures

MN-00-03-2 -- Effect of Data Period-of-Record on Estimation of HVAC&R Design Temperatures ✓ Most Recent

1719280

Conference Proceeding by ASHRAE , 2000

Donald G. Colliver, Ph.D., P.E., Fellow ASHRAE Richard S. Gates, Ph.D., P.E., Member ASHRAE

Track This

Full Description

The determination of accurate design temperature values for a particular location depends on having sufficient long-term quality data for the location. The availability of these data often dictates which locations are included in tables of design conditions. Thus, there is a need to determine the minimum number of years of data needed to determine reasonable esti-mates of design conditions or, if long-term data have already been analyzed, to determine the expected variability in the design values calculated based upon the amount of data used. The variability of the estimation of design conditions for 16 North American locations was investigated by comparing the difference in design conditions obtained from long-term (30 year) period-of-record (POR) data to those determined from subsets of the long-term POR data. The dry-bulb, dew-point, and wet-bulb temperature design conditions were analyzed for 1- to 15-year POR weather data subsets. The analysis demonstrated that if the estimate of the design values were determined using a one-year POR the aver-age of the annually determined design heating values would be slightly warmer (less extreme temperature) and the design cooling values would be slightly cooler (less extreme temper-ature) than using the 30-year POR. However, the range of differences was considerable and demonstrates the masking of variation in design temperatures caused by determining aver-ages for different locations. The 16-location mean and stan-dard deviation of the range in the errors in estimating the design temperatures between a one-year POR and the thirty-year POR indicate that the 99.6% design dry-bulb temperature heating could vary by 10.7±3.7°C (19.3±6.7°F) depending upon which year or location was selected. A POR of at least 12 years must be used to reduce the mean range of differences in design DB, DP, and WB cooling to less than 1°C. In order to reduce the mean range of differences in heating design dry-bulb temperatures to within 2°C, a POR of at least 13 years must be used. However, a considerable range in design condi-tions can still exist with individual stations and depends upon the climate.

Units: Dual

See more

Also Bought By Customers

  • 1712083

    MN-00-16-3 -- Dynamic Ice---Low-Cost Alternative for New ...
    Priced From $16.00

  • 1712086

    MN-00-07-2 -- Experimental Procedure and Uncertainty Anal...
    Priced From $16.00

  • 1719258

    MN-00-10-2 -- Comparative Ventilation Systems Tests in a ...
    Priced From $16.00

  • 1719265

    MN-00-08-1 -- HVAC Systems for Inpatient Rooms
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2000 Annual Conference, Minneapolis, MN > Transactions 2000, Vol. 106, pt. 2 > Symposium Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2000

Number of Pages:

9

File Size:

1 file

Product Code(s):

D-7246

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/mn-00-03-2-effect-of-data-period-of-record-on-estimation-of-hvac-r-design-temperatures?product_id=1719280
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463805045
Order #: None
Cookies: YES
×