accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. NA-2240 -- Hot Water and Steam Heating Selection Factors, Part I: Theoretical Development

NA-2240 -- Hot Water and Steam Heating Selection Factors, Part I: Theoretical Development ✓ Most Recent

1857913

Conference Proceeding by ASHRAE , 1972

Curtis O. Pedersen; Warren S. Harris; Wilbert F. Stoecker

Track This

Full Description

In designing a hydronic system, the output of a boiler usually is made equal to the design heat loss of the building plus additions for added loads, such as piping heat losses and building temperature recovery from a setback condition.

Present practice is to select a boiler having a gross output of 15 to 30% greater than the connected design load. This extra boiler capacity is intended to provide for normal piping losses and to provide some extra capacity for temperature recovery of the system.

If recovery from a setback condition is desired at outdoor design conditions, the boiler may have sufficient capacity due to the added allowance for piping and pickup, but the terminal units may not have sufficient capacity since they are sized on the basis of the design heat loss. Also, if the boiler is operating at its maximum temperature limit, the heat input to the building during recovery is limited by the terminal unit capacity. For these reasons, the terminal units, as well as the boiler, should have increased capacity when used in a system intended for setback operation.

The new capacity of the boiler and terminal units for setback operation can be found by multiplying the design heat loss of the building by a dimensionless term called the selection factor, defined as the ratio of the required system design output to the design heat loss of the building. A single selection factor for all buildings is not correct because of variations in building geometry, materials, and building usage. For example, a massive building whose temperature is to be elevated 10 F in 3 hrs would require a much larger selection factor than a lightly constructed building whose temperature was to be elevated 6 F in 8 hrs. Ideally, the smallest selection factor would be chosen for each installation, resulting in minimum costs while still meeting the desired recovery times.

This paper which is the first part of a two-part set, presents the development of applicable equations and the procedure for translating thermal properties of walls and roof into the parameters needed to obtain numerical results. The companion paper, presents an experimental check of the validity of the proposals and a simplified procedure to facilitate the computation of the selection factor.

Both papers are reports of findings under ASHRAE Research Project 56.

See more

Also Bought By Customers

  • 1857852

    NA-2245 (RP-107) -- Pressure Drop in the Suction Lines of...
    Priced From $16.00

  • 1857855

    NA-2247 -- Local Heat Transfer Coefficients During Annula...
    Priced From $16.00

  • 1857868

    NA-2250 -- Simplified Dynamic Response Relations for Finn...
    Priced From $16.00

  • 1857874

    NA-2252 -- A Simplified Method for the Management of Air-...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 1972 Annual Conference, Nassau, BH > Transactions 1972, Vol. 78, pt. 2 > Technical Papers
  • ASHRAE > Transactions > Transactions 1972, Vol. 78, pt. 2 > Technical Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

1972

Number of Pages:

11

File Size:

1 file

Product Code(s):

D-NA-2240

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/na-2240-hot-water-and-steam-heating-selection-factors-part-i-theoretical-development?product_id=1857913
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463804689
Order #: None
Cookies: YES
×