accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. NFPA (Fire) 780

NFPA (Fire) 780 Historical

1920811  Preview

Standard for the Installation of Lightning Protection Systems, 2017 Edition

standard by National Fire Protection Association , 06/02/2016

This document has been replaced. View the most recent version.

Track This

Full Description

Major changes in the 2017 edition of NFPA 780 provide greater oversight and new understanding of lightning protection systems and lightning hazards.

Reflecting the latest protection methods, devices, and safety challenges, the 2017 edition of NFPA 780: Standard for the Installation of Lightning Protection Systems is the new industry benchmark for protecting lives and property from fire and related dangers associated with lightning events.

Determine the right protection scheme for different occupancies.

Lightning hazards exist everywhere, but depending on the use of a building or structure, different lightning protection protocols exist. This edition of NFPA 780 helps you recognize hazards and provide appropriate protection.

  • Updated Section 5.3 pertaining to facilities that handle or process combustible or explosive dust now presents specific references to NFPA® standards addressing dust hazards, including NFPA 61: Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities, NFPA 122: Standard for Fire Prevention and Control in Metal/Nonmetal Mining and Metal Mineral Processing Facilities, and NFPA 664: Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities.
  • Rewritten Chapter 7 addresses protection for structures containing flammable vapors, flammable gases, or liquids that can give off flammable vapors.
  • New definitions include ground loop conductor, integral lightning protection system, mast-type lightning protection system, rated impulse withstand voltage level (withstand voltage) (u w), smart structure, solar array, and solar panel.

Other changes assist facility managers, installers, inspectors, and AHJs:

  • Added requirements in this edition -- concerning physical on-site inspections of completed installations and periodic inspections or testing -- may be required at the discretion of the AHJ.
  • Updated figures illustrate air terminal protection for lower roof protection.
  • New requirements cover test and connection points for concrete-encased electrodes to enable periodic maintenance and testing of the ground system.
  • New bonding requirements address long horizontal metal bodies on roofs.
  • Numerous new requirements pertain to ungrounded metal bodies.
  • This edition includes re-evaluated and revised zero property line conditions.
  • New Annexes cover technologies used in state-of-the-art systems: Annex J, Protection of Smart Structures; and Annex K, Guide to International Standards Dealing with the Selection of SPDs for Use on Photovoltaic (PV) Installations.

Make sure you're prepared to reduce lightning risks. Trust your jobs to the 2017 NFPA 780.

See more

Also Bought By Customers

  • 2238609

    NFPA (Fire) 232
    Priced From $197.00

  • 2240872

    NFPA (Fire) 18A
    Priced From $197.00

 

Document History

  1. NFPA (Fire) 780

    July 2025
    Standard for the Installation of Lightning Protection Systems, 2026 Edition

    • Most Recent  Most Recent
  2. NFPA (Fire) 780

    March 2022
    Standard for the Installation of Lightning Protection Systems, 2023 Edition

    • Historical Version
  3. NFPA (Fire) 780

    January 2020
    Standard for the Installation of Lightning Protection Systems, 2020 Edition

    • Historical Version
  4. NFPA (Fire) 780

    You are currently viewing this product 👀 currently
    viewing

    June 2016
    Standard for the Installation of Lightning Protection Systems, 2017 Edition

    • Historical Version
  5. NFPA (Fire) 780

    June 2013
    Standard for the Installation of Lightning Protection Systems, 2014 Edition

    • Historical Version
  6. NFPA (Fire) 780

    June 2010
    Standard for the Installation of Lightning Protection Systems, 2011 Edition

    • Historical Version
  7. NFPA (Fire) 780

    October 2007
    Standard for the Installation of Lightning Protection Systems, 2008 Edition

    • Historical Version

Browse related products from National Fire Protection Association

  • National Fire Protection Association > Codes and Standards

Order Options

Delivery Options
Price: $197.00
Ships in 3-5 business days

Product Details

Published:

06/02/2016

ISBN(s):

9781455914210

Number of Pages:

109

Product Code(s):

78017
✕

Document Delivery Options

✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/nfpa-fire-780?product_id=1920811
Referrer: Direct Navigation
IP: 216.73.216.32
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463762846
Order #: None
Cookies: YES
×