accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. OR-20-013 -- Home Envelope Performance Evaluation Using a Data Driven Method

OR-20-013 -- Home Envelope Performance Evaluation Using a Data Driven Method ✓ Most Recent

2113213

Conference Proceeding by ASHRAE , 2020

Junke Wang, Student Member ASHRAE; Choon Yik Tang, PhD; Li Song, PhD, PE, Member ASHRAE

Track This

Full Description

Envelope performance evaluation, namely evaluation ofthe thermal properties (thermal transmittance and capacity)and airtightness are becoming increasingly important forachieving energy efficient homes. Unlike traditional evaluationmethods—such as those based on initial design data,measured structure data from sampling, and in-situ measurementsusing a heat flow meter—the model-based envelopeperformance evaluation method proposed in this paper isbased on a simplified home thermal model. This method canevaluate the overall home envelope thermal performance, i.e.,the integration of thermal properties and airtightness, using ashort period of indoor and outdoor air temperature data.Depending on the availability of the wind or not, this methodcan also evaluate the airtightness of an envelope. Threesequential experiments were conducted to validate the effectivenessof the method. The first experiment showed the windeffect can cause around 15% difference in envelope thermalproperty estimations; the second experiment suggested winddata collected from a city weather station might not be accurateto represent the local wind conditions near the test home;and the third experiment, using data collected from 1,676homes, demonstrated that the envelope performancedecreased proportionally as the home age increased for homesthat were 5 to 40 years old, while there were no distinctivepatterns for homes older than 40 years due, perhaps, to a smallsample size. The demonstrated results of the third experimentalign well with the expectation that younger homes experiencebetter home envelope thermal performance. Although moreexperiments are needed, with knowledge of the ground-truth ofthe test home envelope conditions, the results of this papershow that the model-based envelope performance evaluationmethod can be an efficient, practical, and effective alternativeto the traditional methods by eliminating physical heat flow orconstruction material property measurements. See more

Also Bought By Customers

  • 2113205

    OR-20-003 -- Quantifying Risk with Selection of the Natu...
    Priced From $16.00

  • 2113208

    OR-20-007 -- 25 Year Evolution of a Worldwide Building En...
    Priced From $16.00

  • 2113211

    OR-20-010 -- Effect of Water Consumption on Optimal Contr...
    Priced From $16.00

  • 2115728

    OR-20-C034 -- A Novel Simulation Framework for Comfort-ba...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2020 Winter Conference, Orlando, FL > Transactions 2020, Vol 126 pt. 1 > Technical Papers
  • ASHRAE > Transactions > Transactions 2020, Vol. 126, pt. 1 > Transactions Volume > Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2020

Number of Pages:

12

Units of Measure:

Dual

File Size:

1 file

Product Code(s):

D-OR-20-013

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/or-20-013-home-envelope-performance-evaluation-using-a-data-driven-method?product_id=2113213
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463804784
Order #: None
Cookies: YES
×