accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. RP-1544 -- Establishing Benchmark Levels and Patterns of Commercial Hot Water Use - Hotels

RP-1544 -- Establishing Benchmark Levels and Patterns of Commercial Hot Water Use - Hotels ✓ Most Recent

1900399

Report / Survey by ASHRAE , 2015

Track This

Full Description

Water heating represents a significant amount of energy use in the Hotel/Motel sector yet information currently used for designing and sizing hotel/motel water heating systems predates modern energy efficient fixtures and appliances such as low-flow shower heads and efficient clothes and dish washers. Moreover, existing hotel/motel hot water system design practices have been conservative because information on hot water use has been lacking. The purpose of this work was both to collect detailed hot water use data from two hotels which could be used to update hotel hot water system design practices, and to develop data collection and analysis approaches which could be used by others to collect similar information in order to expand our knowledge of how hot water is used in hotels.

This report describes the data collection and analysis approaches developed in sufficient detail that others may duplicate what was done. These fairly low-cost monitoring approaches are easily installed without plumbing or electrical modifications, yet allow collection of details on individual fixture and appliance hot water end use draw patterns, and their time diversity throughout the day and throughout the year.

This report also presents data from one average size "travel" hotel and one medium size "business" hotel. The business hotel used 2.6 million gallons (9.8x106 liters) of hot water during the 13 month test program, while the travel hotel used 769,000 gallons (2.9x106 liters) of hot water. This work showed that design day number of guests per room and bathing behaviors were similar for the two hotels tested. Hence the portion of overall hotel hot water use due to guest room (bathing + sink + cleaning) scales well with number of guests and is likely similar for most hotels. However, it was also learned that hotels additionally have a significant amount of hot water use that is not proportional to occupancy, rather being most likely used for cleaning and other support of non-guest-room areas and equipment such as meeting rooms and food service facilities. Thus hotel hot water use is not just proportional to number of guests or occupied rooms; there is a significant portion of hot water use that is independent of occupancy.

Importantly, this report normalizes the hot water use results and shows a procedure allowing designers to perform heating rate vs storage volume system design and sizing trade offs for hotels of different sizes than studied here. Additionally, the report disaggregates hot water use by several end use categories such as commercial clothes washing machines, dishwashing machines, bathing, cleaning operations, and sink use, and then presents design information with and without some of those end use categories so that readers can appropriately design hotels with vs without some of those end uses.

One important finding from this work is that bathing events do not overlap nearly to the extent apparently assumed during sizing of piping to serve guest room hot water circuits. As a result it appears that some piping systems use much larger diameter piping than needed. Using smaller diameter piping could result in a significant reduction in initial costs. The report shows a simple method of determining peak design dayhot water flow rates for use in sizing piping.

Applications, Values, and Use
Results of this work can be used to better design hotel/motel potable hot water systems, and to allow others to collect similar data so that design information can be expanded.

See more

Also Bought By Customers

  • 1864194

    RP-1550 -- Thermal Performance of Selected Insulating Coa...
    Priced From $32.00

  • 1868095

    RP-1517 -- Validation of a Low-Odor Acoustic Model of Boi...
    Priced From $32.00

  • 1871043

    RP-1547 -- CO2-Based Demand Controlled Ventilation for Mu...
    Priced From $32.00

  • 1874798

    RP-1584 -- Developing Alternative Approaches to Predictin...
    Priced From $32.00

Browse related products from ASHRAE

  • ASHRAE > Research Reports > Research Reports 1500-1599

Order Options

Delivery Options
Price: $32.00
Available for Immediate Download

Product Details

Published:

2015

Number of Pages:

236

Units of Measure:

Dual

File Size:

1 file

Product Code(s):

D-RP-1544

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/rp-1544-establishing-benchmark-levels-and-patterns-of-commercial-hot-water-use-hotels?product_id=1900399
Referrer: Direct Navigation
IP: 216.73.216.61
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463809497
Order #: None
Cookies: YES
×