accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. SD-95-09-2 -- Design of Multi-Coil Run-Around Heat Exchanger Systems for Ventilation Air Heating and Cooling

SD-95-09-2 -- Design of Multi-Coil Run-Around Heat Exchanger Systems for Ventilation Air Heating and Cooling ✓ Most Recent

1716331

Conference Proceeding by ASHRAE , 1995

Johnson, A. B., Besant, R. W., Schoenau, G. J.

Track This

Full Description

It is the objective of this investigation to design and simulate multiple-coil run-around systems under a wide range of operating conditions from cold weather heat recovery to hot weather operation with high cooling loads. A computer program has been developed to simulate any number of supply and exhaust coils in a run-around heat recovery system. The simulation enables the rating of a run-around system based on known physical parameters of each coil, the supply and exhaust air flow rates, inlet supply air temperature and humidity levels, and inlet exhaust air temperature and humidity levels. The simulation program is used in two different manners - it can be used for a specified system, to determine yearly costs and savings by using hourly weather files; and to determine the least objective function based on the life-cycle cost of the system to select design parameters for the run-around system. The yearly simulation uses hourly weather data to determine hourly operating costs and savings, all liquid and air temperatures, and pressure drops in the system. The results show that the performance of an optimised system with two coils is basically the same as the performance of a four coil optimised run-around system with the same total air flows as the two coil system. For the typical building application studied, the life-cycle cost of the optimised systems is 13% less than the life-cycle cost of an original installed run-around system. With evaporative cooling, the life-cycle cost of an optimised system is 24% less than that of the original installed system. For all the heat recovery systems analysed, the payback period is less than 3.4 years.

KEYWORDS: year 1995, designing, run around coils, heat exchangers, air change rate, modernising, heat recovery, computer programs, calculating, rating, performance, payback period, air flow rate, service life, costs, economics, sizing, optimisation, comparing

See more

Also Bought By Customers

  • 1716270

    SD-95-04-3 -- Surface Cooling in Hospitals: Use of Comput...
    Priced From $16.00

  • 1716335

    SD-95-11-1 -- Single-Phase Heat Transfer and Pressure Dro...
    Priced From $16.00

  • 1716369

    SD-95-15-3 -- Identification of Oils to be Sprinkled in L...
    Priced From $16.00

  • 1716370

    SD-95-15-4 -- Estimation of Comfortable Temperatures for ...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 1995 Annual Conference, San Diego, CA > Transactions 1995, Vol. 101, pt. 2 > Symposium Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

1995

File Size:

1 file

Product Code(s):

D-17233

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/sd-95-09-2-design-of-multi-coil-run-around-heat-exchanger-systems-for-ventilation-air-heating-and-cooling?product_id=1716331
Referrer: Direct Navigation
IP: 216.73.216.61
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463808708
Order #: None
Cookies: YES
×