accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. Seminar 43 - New Advances in Ground-Source Borehole Thermal Response Testing and Storage Applications

Seminar 43 - New Advances in Ground-Source Borehole Thermal Response Testing and Storage Applications ✓ Most Recent

2008224

Conference Proceeding by ASHRAE , 2018

Cary Smith; Xiaobing Liu, Ph.D.; Rick Clemenzi; Garen N. Ewbank

Track This
👥 Multi-User PDF
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

Track: Fundamentals and Applications
Sponsor: 6.8 Geothermal Heat Pump and Energy Recovery Applications
Chair: Cary Smith, Member, Sound Geothermal Corp., Sandy, UT

Borehole thermal resistance is the most important field measured component in the loopfield design. Advancements in measurement and heat storage/recovery enable more detailed information to the design engineer and adds forensic tools. The advanced analytical tool extracts more information from the thermal conductivity test in a shorter amount of time. Thermal regimes, such as grout conductivity, can be identified, and stability of the power source is less important. Advances in borehole thermal storage (BTS) management permit more precise use of the heat stored and being stored. This seminar presents the latest advancement in storage management and measurement.

1. Dynamic Determination of Ground Thermal Conductivity and Minimum Thermal Response Test Duration Using theLine Source Model
Xiaobing Liu, Ph.D., Member, ORNL, Oak Ridge, TN
The effective ground thermal conductivity (GTC) is a critical design parameter for sizing ground heat exchangers (GHXs) of ground source heat pump (GSHP) systems. GTC is usually determined with a thermal response test (TRT) and inverse modeling. The current practice requires extremely stable power supply for 36-48 hours during a TRT. A new method is developed to dynamically analyze the TRT data during the test. With this method, the TRT duration could be shortened by 20 to 40% while retaining similar accuracy in the determined GTC value as the current practice.

2. Simulation Correlation Analysis Method Capabilities and Continuous Line-Slope Method Findings
Rick Clemenzi, Geothermal Design Center Inc., Ashville, NC
Current TRT is limited to only determining approximate Ground Thermal Conductivity. Other ground parameters are assumed to be "as reported by the requester, driller, and grouter". Correct Grout TC is critical to an efficiently operating GHP system, yet poor grouting quality is common. The new Simulation Correlation Analysis Method for the first time also determines Grout TC and confirms loop type and length for test wells or for installation Quality Assurance. The new method also removes the necessity of steady power/heat input -- a requirement of the current Line-Slope TRT method, opening new doors for Commissioning and System Validation Testing.

3. Advanced Thermal Response Applications
Garen N. Ewbank, Member, Ewbank Geo Testing, LLC, Fairview, OK
Ground Heat Exchangers (GHEX) are a system component of a convective circulation circuit (or Ct3). The GHEX is a renewable resource of heat and a storage device for wasted heat. To quantify the performance, capacity, and duration of the resource and storage one should be capable of forecasting the thermal response within the Ct3 to insure performance and operation. The use of the Dynamic Determination of Ground Thermal Conductivity and Minimum Thermal Response Test Duration Using the Line Source Model allows the designer to model hourly responses within the heat flux of the Ct3.

4. Utilizing DTS for DTRS and Ghx/Btes Temperature Instrumentation
Chuck Hammock, P.E., Associate Member, Andrews, Hammock & Powel, Inc., Macon, GA
Traditional Thermal Response Tests (TRT), aka Thermal Conductivity Tests (TCT), are limited to determining only an average ground thermal conductivity "k" factor of the formation. By deploying fiber optic based Distributed Temperature Sensing (DTS) cable inside the U-bend, "distributed" thermal conductivity values can be resolved at much more granular levels (typically every two meters) via this "Distributed TRT" or DTRT methodology. DTS systems can also be utilized to instrument traditional/non-traditional Groundloop Heat Exchangers (GHX) for temperature monitoring/control of these systems. This session provides a brief introduction/overview of the technology and real world examples of their use.

Presented: Tuesday, January 23, 2018, 11:00 AM-12:30 PM
Run Time
: 90 min.

This is a zip file that consists of PowerPoint slides synchronized with the audio-recording of the speaker (recorded presentation), PDF files of the slides, and audio only (mp3) for each presentation.

See more

Also Bought By Customers

Also Bought By Customers…

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2018 Winter Conference, Chicago, IL > Seminar Recordings > Seminars

Order Options

Delivery Options
Price: $52.00
Available for Immediate Download

Product Details

Published:

2018

Units of Measure:

Dual

File Size:

1 file , 150 MB

Product Code(s):

D-CH18Sem43

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/seminar-43-new-advances-in-ground-source-borehole-thermal-response-testing-and-storage-applications?product_id=2008224
Referrer: Direct Navigation
IP: 216.73.216.209
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463994269
Order #: None
Cookies: YES
×