accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. TIA-455-200

TIA-455-200 ✓ Most Recent [ Active ]

3037406

FOTP-200 Insertion Loss of Connectorized Polarization-Maintaining Fiber or Polarizing Fiber Pigtailed Devices and Cable Assemblies

standard by Telecommunications Industry Association , 09/19/2001

Track This
👥 Multi-User PDF
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

Introduction

Intent

This Standard specifies a procedure for the measurement of the insertion loss of a fiber optic interconnection on single mode, highly linearly birefringent optical fiber, i.e. either polarization-maintaining fiber (PMF) or polarizing fiber (PZF). The connector can be mounted on the PMF/PZF pigtail of a component or part of a cable assembly. Insertion loss, as used in this Standard, is the measured attenuation of the interconnection, expressed in decibels. The method described in this Standard is the PMF/PZF equivalent of ANSI/TIA/EIA-455-171 Method D with the insertion loss reported as a positive number.

Definitions

For the purposes of this Standard, the following definitions apply.

Birefringence.

The property of a material in which orthogonal light polarizations have different indices of refraction, which cause the light at those polarizations to travel at different speeds (also referred to as the fast and slow axes). Linearly birefringent fiber maintains linear polarization states along the length of the fiber. Unstable birefringence in standard single-mode fiber causes the states of polarization to behave in an unpredictable way. Polarization-maintaining fibers are a special class of single-mode fibers with a highly birefringent waveguide structure that maintain the polarization states across the length of the fiber.

Polarizer/Analyzer.

An optical element designed to transmit light of a single polarization state -- most commonly, a linear state. When a polarizer is placed at the output of an optical system, it is called an analyzer.

Extinction.

The ratio of the optical power passed in the transmitted polarization state to the power passed in the orthogonal polarization state. The extinction of a polarizing element is measured with unpolarized light incident.

Polarization Crosstalk.

The ratio of the power that crosses over to the initially unexcited polarization state to the power that remains in the initially excited state (both powers measured at the element’s distal end). The polarization crosstalk of a birefringent element is measured with polarized light, aligned to be parallel to either of the element’s principal axes, incident.

Polarization-Maintaining Fiber (PMF).

A class of highly linearly birefringent single-mode fiber, unlike the common variety of low birefringence, single-mode fiber used in telecommunication networks. PMF is used to guide linearly polarized light from point to point, that is, to ensure that polarization does not change with distance. the birefringence of commercial PMF is stress-induced by placing the core between or within glass elements of different physical composition, or by forming a non-round core.

Polarizing Fiber (PZF).

A highly birefringent optical fiber in which only one polarization state is propagated with low attenuation.

Principal Optical Axes.

Those optical axes for which the speed of light in a linearly birefringent material is a maximum or a minimum.

Slow Axis. The optical axis of a PMF or PZF which is aligned to the stress rods (as in PANDA or Bow-tie fiber), the stress region (as in Oval stress region fiber), or the major axis of an elliptical core fiber. For PMF to be actually polarization maintaining, linearly polarized light must be aligned with one of the axes, commonly the slow axis. By convention, the anti-rotation key of the connector should be aligned with the slow axis as defined in FOCIS-4A and to be followed for other connector types.

Device Under Test (DUT).

The specimen, or device, under test.

Laser Diode (LD).

Optical power source incorporating a typically coherent laser diode as its basic emitting device.

Light-Emitting Diode (LED).

Optical power source incorporating a noncoherent light-emitting diode as its basic emitting device.

See more

Also Bought By Customers

Also Bought By Customers…

 

Document History

  1. TIA-455-200

    You are currently viewing this product 👀 currently
    viewing

    September 2001
    FOTP-200 Insertion Loss of Connectorized Polarization-Maintaining Fiber or Polarizing Fiber Pigtailed Devices and Cable Assemblies

    • Most Recent  Most Recent
  2. TIA ANSI/TIA-455-200

    September 2001
    FOTP-200 Insertion Loss of Connectorized Polarization-Maintaining Fiber or Polarizing Fiber Pigtailed Devices and Cable Assemblies

    • Historical Version
  3. TIA ANSI/TIA/EIA-455-200

    September 2001
    FOTP-200 Insertion Loss of Connectorized Polarization-Maintaining Fiber or Polarizing Fiber Pigtailed Devices and Cable Assemblies

    • Historical Version

Order Options

Delivery Options
Price: $101.00
Available for Immediate Download

Product Details

Edition:

01#

Published:

09/19/2001

Reaffirmed:

10/08/2025

Number of Pages:

30

File Size:

1 file

Note:

This product is restricted and cannot be purchased in these countries.
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.
✕

Restricted Countries

Belarus, Cuba, Iran, Nicaragua, North Korea, Russia, Sudan, Syria, Ukraine, Venezuela
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/tia-tia-455-200?product_id=3037406
Referrer: Direct Navigation
IP: 216.73.217.50
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1464073990
Order #: None
Cookies: NO
×