accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. TO-22-C034 - Heating Degree Days Relevancy: Why a 55-Degree Balance Point is Better than 65 for Building Energy Analysis in Heating Dominant Climates

TO-22-C034 - Heating Degree Days Relevancy: Why a 55-Degree Balance Point is Better than 65 for Building Energy Analysis in Heating Dominant Climates ✓ Most Recent

2507083

Conference Proceeding by ASHRAE , 2022

Mark Heizer, PE, LEED AP, Member ASHRAE; Kelly Thomas, LEED AP BD+C, Member ASHRAE

Track This

Full Description

Heating Degree Days at 65F (HDD65) is still utilized by ASHRAE Standard 169 for determining Climate Zones and in other fundamental HVAC resources, such as Air Conditioning Contractors of America’s (ACCA's) Manual J and S calculations. The U.S. Energy Information Administration (EIA) also uses HDD65 and it even occurs within the Passive House Institute US (PHIUS) where heating is not in demand until Outdoor Air Temperatures (OAT) reach 45F. This paper explores and supports utilization of Heating Degree Days at 55°F (HDD55) for building energy analysis in heating dominant climates. This is supported by EnergyPlus modeling results for a sample of building types. A degree days overview on Energycap states that "The 65-degree balance point standard was developed 75 years ago to help the gas industry predict heating loads in residences. Studies back then showed that when the average daily temperature fell below 65F, residences began turning on the heat." Today, HDD65 doesn’t reflect structures built to modern energy codes, because internal loads are offsetting thermal envelope losses and when combined with the continued tightening of ventilation energy recovery requirements, heating is not necessary until much cooler than 65F. According to a Regional Technical Forum (RTF) presentation titled "Overview of Updated Commercial EnergyPlus Building Models and Alignment with CBSA Data" dated August 31, 2021, the 'apparent balance point range between 50-60F’ was the reasonable OAT before heating was utilized by occupants. When energy modeling to HDD65, decisions are being made relative to temperature ranges that have minimal impact on building energy use. For example, when the OAT is in the 50-65F range, this may mean more economizer hours are available without having to reheat the outdoor air or heat exterior spaces/operating zones. This would decrease the amount of energy the building utilizes, allowing for more accurately sized equipment. Similarly, utilizing Cooling Degree Day's at 50F (CDD50), as ASHRAE Standard 169 does to determine Climate Zones, to predict cooling loads isn’t appropriate as most building types don’t need cooling starting at 50F. Economizers are essentially mandatory for larger buildings which might need cooling at 50F OAT, but smaller buildings will possibly be in heating mode when the OAT is 50F. Utilizing CDD in the range of 60-70F would give a more accurate representation of required cooling loads and will also be a minor focus of this technical paper. New HDD and CDD figures should be produced for ASHRAE Standard 169, Technical Resource Manuals (TRM's), and other publications that utilize degree days. With this information, end users can better analyze the weather's impact on actual building energy usage and better determine equipment sizing and other impacts. See more

Also Bought By Customers

  • 2507062

    TO-22-C010 - Addressing the Housing Challenges of Rural A...
    Priced From $16.00

  • 2507066

    TO-22-C015 - Variations in Residential Building Electrici...
    Priced From $16.00

  • 2507071

    TO-22-C021 - Chemical Stability Investigations of Ultra-L...
    Priced From $16.00

  • 2507076

    TO-22-C027 - Development of a Hardware-in-the-Loop Testbe...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 2022 Annual Conference, Toronto, ON > Conference Papers > Annual Conference Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

2022

Number of Pages:

9

Units of Measure:

Dual

File Size:

1 file

Product Code(s):

D-TO-22-C034

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/to-22-c034-heating-degree-days-relevancy-why-a-55-degree-balance-point-is-better-than-65-for-building-energy-analysis-in-heating-dominant-climates?product_id=2507083
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463804694
Order #: None
Cookies: YES
×