accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. TO-98-04-2 -- District Energy as a Response to Climate Change: The Experience in Europe and the Potential in America

TO-98-04-2 -- District Energy as a Response to Climate Change: The Experience in Europe and the Potential in America ✓ Most Recent

1711167

Conference Proceeding by ASHRAE , 1998

Robert E. McCabe, P.E.; Morris A. Pierce, Ph.D.; B. Jeffrey Price

Track This

Full Description

Climate change has the potential to be the most serious problem that our civilization faces, and the greenhouse gases responsible for the danger are due to human activities. District energy is a concept that results from combining district heating and cooling with the generation of electricity. District energy can play an important role in the climate-change strategies under consideration by policy makers by offering a technology to significantly reduce CO2 emissions. The well-documented economic and environmental benefits of a district energy system utilizing various combinations of simultaneous generation of heat, chilled water, and electricity are discussed briefly in this paper. An overview of the technological innovations, applications, and future trends in district energy systems with cogeneration is provided, particularly as they relate to the renovation and replacement of existing systems. At the present time, district energy is underutilized and serves only 1.3% of the U.S. energy needs. This paper presents a simple model for implementing increased utilization of district energy in the U.S. based on the experience in comparable European Union (EU) countries. Attainment of the Kyoto Climate Change Protocol, the 7% reduction of CO2 emissions from 1990 levels by the year 2012, is discussed in the context of the potential contribution of increased utilization of district energy. By reaching par with comparable EU countries, the U.S. could achieve a 3% reduction in total national CO2 emissions. With 100% implementation of district energy serving the heating market sector, the U.S. could achieve an 8.5% reduction in CO2 emissions. Further significant reduction in CO2 is possible with district energy concepts by redirecting national policy on the use of internal combustion engines through integration of the transportation energy sector with industrial, building, and power plant sectors; a major electrification of our transportation infrastructure would likely result. Increased implemen tation of district energy thereby addresses the risks posed by current global climate change theories and is a necessary condition for the U.S. to achieve CO2 emission reductions.

Units: Dual

See more

Also Bought By Customers

  • 1711169

    TO-98-04-4 -- Improving Cogeneration Plant Performance Th...
    Priced From $16.00

  • 1711178

    TO-98-07-3 -- A Design Method for Hybrid Ground-Source He...
    Priced From $16.00

  • 1711182

    TO-98-08-4 -- Building Cavities Used as Ducts: Air Leaka...
    Priced From $16.00

  • 1711352

    TO-98-17-2 -- Instrumentation and Measurement of Airflow ...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 1998 Annual Conference, Toronto, ON > Transactions 1998, Vol. 104, pt. 2 > Symposium Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

1998

Number of Pages:

10

File Size:

1 file

Product Code(s):

D-7697

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/to-98-04-2-district-energy-as-a-response-to-climate-change-the-experience-in-europe-and-the-potential-in-america?product_id=1711167
Referrer: Direct Navigation
IP: 216.73.216.61
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463810837
Order #: None
Cookies: YES
×