accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. TO-98-18-3 -- Experimental and Analytical Evaluation of a Ground-Coupled Refrigerator-Freezer

TO-98-18-3 -- Experimental and Analytical Evaluation of a Ground-Coupled Refrigerator-Freezer ✓ Most Recent

1711355

Conference Proceeding by ASHRAE , 1998

Edward A. Vineyard, P. E.; J. Benjamin Horvay, P.E.; Edward R. Schulak

Track This

Full Description

In April 1997 the U.S. Department of Energy (DOE) promulgated the third refrigerator-freezer standard in a series dating back to 1990. The standard, which takes effect in July 2001, requires manufacturers to reduce energy consumption by an average of 30%, compared to 1993 models. In addition, global concerns over greenhouse gases have prompted the elimination of hydrochlorofluorocarbon R-141b, used as a foam blowing agent in refrigerator cabinet insulation, by January 2003. The leading replacement candidate at this time, hydrofluorocarbon R-245a, is expected to have a minimal impact on energy consumption. However, should it fail to be a viable candidate due to toxicity or other concerns, additional replacements, such as cyclopentane or hydrofluorocarbons R-134a or R-134, would result in energy penalties ranging from 8% to 12%. These potential penalties, coupled with the 2001 standard, would require appliance manufacturers to reduce energy consumption approximately 40% in the next five years.

In response to efforts to reduce refrigerator-freezer energy consumption, several design options based on using a ground-source heat exchanger as a means of rejecting heat from the cabinet and condenser were investigated for improving the energy efficiency of a 15.5 ft3 (440 L) domestic refrigerator-freezer. The options included (1) a cooling circuit throughout the cabinet to reduce the cabinet heat gain, (2) a liquid-cooled condenser and smaller compressor, and (3) a secondary cooling circuit in the fresh food section during winter operation. An additional option, increasing the cabinet volume by reducing the insulation thickness, was also investigated as a means of reducing costs. This was accomplished by using the cooling circuit to maintain the same cabinet heat gain as for the original baseline cabinet rather than reduce energy consumption. The modeled results for all the options show that the energy consumption could be reduced by 24.0% with a cabinet cooling circuit, 40.4% with the addition of a liquid-cooled condenser and smaller compressor, and 51.1% from utilizing a fresh food cooling circuit during winter operation. Modeling simulations also show that the cabinet volume could be increased by 2.4 ft3 (70 L), a 15.3% increase, by utilizing the cabinet cooling circuit to reduce the insulation thickness rather than reduce energy consumption. These improvements do not account for the pumping power required for circulating the coolant. In addition to the modeling exercise, a laboratory prototype was fabricated and tested to experimentally verify the energy consumption of a unit with a cabinet cooling circuit. The resulting energy consumption was 1.35 kWh/d, a substantial energy-efficiency improvement of 24.0% compared to the 1997 model baseline unit (1.78 kWh/d). Abbreviated test results with the addition of a liquid-cooled condenser and smaller compressor show a savings of 39.9% (1.07 kWh/d).

Units: Dual

See more

Also Bought By Customers

  • 1711159

    TO-98-01-4 -- Comparison of Heating and Cooling Energy Co...
    Priced From $16.00

  • 1711174

    TO-98-06-2 -- Higher Efficiencies by Means of Variable-Sp...
    Priced From $16.00

  • 1711177

    TO-98-07-2 -- Groundwater Source Technology Application f...
    Priced From $16.00

  • 1711178

    TO-98-07-3 -- A Design Method for Hybrid Ground-Source He...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 1998 Annual Conference, Toronto, ON > Transactions 1998, Vol. 104, pt. 2 > Symposium Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

1998

Number of Pages:

8

File Size:

1 file

Product Code(s):

D-7752

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/to-98-18-3-experimental-and-analytical-evaluation-of-a-ground-coupled-refrigerator-freezer?product_id=1711355
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463804486
Order #: None
Cookies: YES
×