accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. 4153 -- A New Experimental Approach for the Evaluation of Domestic Ventilation Systems, Part 2-Necessary Airtightness Levels, Inner Door Conditions, and Temperature Difference for Successful Function of Nonduct Exhaust-Only Ventilation System

4153 -- A New Experimental Approach for the Evaluation of Domestic Ventilation Systems, Part 2-Necessary Airtightness Levels, Inner Door Conditions, and Temperature Difference for Successful Function of Nonduct Exhaust-Only Ventilation System ✓ Most Recent

1711412

Conference Proceeding by ASHRAE , 1998

Yoshinori Taniguchi, Takao Sawachi, Shigeki Ohnishi, Haruki Ohsawa, Hironao Seto

Track This

Full Description

This paper discusses in detail the behavior of a nonduct exhaust-only ventilation system in an experimental house for which the outflow-inflow paths (i.e., simple openings such as vents and cracks in the envelope, undercuts in inner doors) are modeled by very simple cylinders. The test equipment presented here is composed of a full-scale house model located in an artificial climate chamber where the influence of wind is minimized as much as possible, thereby offering accurately controlled internal-external temperature differences. A series of experiments with this equipment has made it possible to evaluate the effects of various parameters under the same conditions (airtightness of house, size of undercuts in inner doors, internal-external temperature difference), which was impossible in the on-site measurements.

From experimental results, it has been demonstrated that in an extremely airtight house, stable ventilation almost unaffected by an internal-external temperature difference can be achieved by a nonduct exhaust-only ventilation system with a single exhaust fan continually operated, if suitable door undercuts are provided. It has also been verified that at a certain low level of airtightness, the system does not work efficiently, and that in a house where the area of cracks in the envelope is too large, sufficient negative pressure cannot be generated by a single fan. Such a house is, therefore, unsuitable for being ventilated by the exhaust-only technique.

Units: SI

See more

Also Bought By Customers

  • 1711386

    4102 (RP-833) -- Demonstration Knowledge Base to Air Buil...
    Priced From $16.00

  • 1711390

    4122 (RP-622) -- Determination of Coil Defrosting Loads: ...
    Priced From $16.00

  • 1711397

    4134 -- Potential of the Zeotropic Mixture R-22/R-142b in...
    Priced From $16.00

  • 1711408

    4149 -- Effectiveness of a Municipal Ground-Coupled Rever...
    Priced From $16.00

Browse related products from ASHRAE

  • ASHRAE > Conferences > ASHRAE Conferences > 1998 Winter Conference, San Francisco, CA > Transactions 1998, Vol. 104, pt. 1 > Technical Papers
  • ASHRAE > Transactions > Transactions 1998, Vol. 104, pt. 1 > Technical Papers

Order Options

Delivery Options
Price: $16.00
Available for Immediate Download

Product Details

Published:

1998

Number of Pages:

13

File Size:

1 file

Product Code(s):

D-7818

Note:

This product is restricted and cannot be purchased in the following countries Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/4153-a-new-experimental-approach-for-the-evaluation-of-domestic-ventilation-systems-part-2-necessary-airtightness-levels-inner-door-conditions-and-temperature-difference-for-successful-function-of-nonduct-exhaust-only-ventilation-system?product_id=1711412
Referrer: Direct Navigation
IP: 216.73.216.61
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463810455
Order #: None
Cookies: YES
×