accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CAN/CSA E1008-1-98 (R2003)

CAN/CSA E1008-1-98 (R2003) ✓ Most Recent

944428

Residual Current Operated Circuit-Breakers Without Integral Overcurrent Protection for Household and Similar Uses (RCCBs) - Part 1: General Rules (Adopted IEC 1008-1:1990, first edition, including Amendment 1:1992 and Amendment 2:1995, with Canadian deviations)

standard by Canadian Standards Association / National Standard of Canada , 02/16/2000

Track This

Full Description

1. Scope

This International Standard applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating overcurrent protection (hereafter referred to as RCCB's), for rated voltages not exceeding 440 V a.c. and rated currents not exceeding 125 A, intended principally for protection against shock-hazard.

These devices are intended to protect persons against indirect contact, the exposed conductive parts of the installation being connected to an appropriate earth electrode. They may be used to provide protection against fire hazards due to a persistent earth fault current, without the operation of the overcurrent protective device.

RCCB's having a rated residual operating current not exceeding 30 m A are also used as a means for additional protection in case of failure of the protective means against electric shock.

This standard applies to devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value.

NOTES: (1) The requirements for RCCB's are in line with the general requirement s of IEC 755. RCCB's are essentially intended to be operated by uninstructed persons and designed not to require maintenance. They may be submitted for certification purposes. (2) Installation and application rules of RCCB's are given in IEC 364. (3) RCCB's within the scope of the present standard are considered as suitable for isolation (see 8.1.3).

Special precautions (e.g. lightning arresters) may be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines) (see IEC 364-4-443).

NOTE 4 - For RCCB's having a degree of protection higher than IP20 special constructions may be required.

Particular requirements are necessary for - Residual current operated circuit-breakers with integral ove rcurrent protection (see IEC 1009); - RCCB's incorporated in or intended only for association with plugs and socket-outlets or with appliance couplers for household or similar general purposes.

NOTE 5 - For the time being, for RCCB's incorporated in, or intended only for socket-outlets or plugs, the requirements of this s tandard in conjunction with the requirements of IEC 884-1 may be used as far as applicable.

The requirements of this standard apply for normal environmental conditions (see 7.1). Additional requirements may be necessary for RCCB's used in locations having severe environmental conditions.

RCCB's including batteries are not covered by this standard.

This Standard applies to the safety of equipment designed to be installed and used in accordance with the Rules of the Canadian Electrical Code, Part I.

The Canadian Electrical Code, Part I, contains Rules that mandate the installation of ground fault circuit interrupters, as follows: Class A, which has a specific characteristic curve defined in terms of tripping time versus leakage current, as shown in Annex AA. These ground fault circuit interrupters are designed for protection of personnel.

The devices covered by this standard shall not be permitted to be used where the Canadian Electrical Code, Part I, mandates the installation of a Class A ground fault circuit interrupter that is constructed, tested, and marked in accordance with CSA Standard C22.2 No. 144. The devices covered in this standard are permitted to be used only where the Canadian Electrical Code, Part I, does not require a Class A ground fault circuit interrupter.

Portable RCCBs of the direct plug-in type or a cord-connected type shall not be designed for use with a receptacle that is shown in Diagram D1 or D2 of the Canadian Electrical Code, Part I.

Portable RCCBs of the direct plug-in type or cord-connected type shall not have an output receptacle configuration as shown in Diagram D1 or D2 of the Canadian Electrical Code, Part 1.

Devices complying with this Standard shall not be designed for installation in outlet boxes.

Notes: (1) Manufacturers designing products for use in Canada may find a helpful summary of the equipment-related requirements of the CEC, Part I, in CSA Publication SPE-2000. (2) The nomenclature used in CEI/IEC 1008-1 does not match the nomenclature used in the Canadian Electrical Code, Part I. The device termed a ""residual current circuit breaker"" (RCCB) in CEI/IEC 1008-1 corresponds to a ""Ground Fault Circuit Interrupter"" (GFCI) in the Canadian Electrical Code, Part I. (3) This Standard is not to be used for the evaluation of a Class A GFCI. (4) GFCIs covered by this Standard are only permitted to be used where the Canadian Electrical Code, Part I does not mandate the use of a Class A GFCI for protection of personnel. The definition of a Class A GFCI, and its trip current/trip time characteristics are contained in Appendix B of the CEC, Part I. The applicable notes are attached as Annex AA. The devices covered by this Standard can be used for protection of equipment and are not permitted to be used in lieu of a Class A GFCI for personnel protection.

Canadian Deviations are included in this Standard. See more

Also Bought By Customers

  • 19153

    CAN/CSA Z434-03 (R2013)
    Priced From $181.00

  • 944533

    CAN/CSA E79-6-95 (R1999)
    Priced From $47.00

  • 944671

    CAN/CSA Z243.150-88 (R1999)
    Priced From $126.00

  • 944898

    CAN/CSA-ISO/IEC 10611-5-95 (R1999)
    Priced From $90.00

Browse related products from Canadian Standards Association / National Standard of Canada

  • CSA Group > Other

Order Options

Delivery Options
Price: $325.00
Available for Immediate Download

Product Details

Published:

02/16/2000

Number of Pages:

81

File Size:

1 file

Note:

This product is restricted and cannot be purchased in the following countries Russia, Ukraine, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/can-csa-e1008-1-98-r2003?product_id=944428
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463798287
Order #: None
Cookies: NO
×