accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. CSA N288.1:20 (R2025)

CSA N288.1:20 (R2025) ✓ Most Recent

2107585  Preview

Guidelines for modelling radionuclide environmental transport, fate, and exposure associated with the normal operation of nuclear facilities, Includes Errata (2020), Errata (2022) and Update No. 1 (2024)

standard by CSA Group , 03/01/2020

Track This

Full Description

Preface:

This is the fourth edition of CSA N288.1, Guidelines for modelling radionuclide environmental transport, fate and exposure associated with the normal operation of nuclear facilities. It supersedes the previous editions published in 2014, 2008, and 1987 under the title, Guidelines for calculating derived release limits for radioactive material in airborne and liquid effluents for normal operation of nuclear facilities.

Major changes to this edition include
a) updated the structure of these Guidelines for increased consistency within the CSA N288 series;
b) removed administrative language from the Guidelines;
c) provided additional clarification in areas identified by users;
d) identified stable carbon data for aquatic plants and invertebrates;
e) improved consistency of language throughout the Guidelines; and
f) updated the guidance on transfer factors.

The COG background document (Hart, 2013) was revised in concert with the fourth edition; the updated version is referred to hereafter as the COG Derived Release Limits Guidance or CDG (Hart, 2019).

Users of these Guidelines are reminded that the site selection, design, manufacture, construction, installation, commissioning, operation, and decommissioning of nuclear facilities in Canada are subject to the Nuclear Safety and Control Act and its Regulations.

The CSA N-Series Standards provide an interlinked set of requirements for the management of nuclear facilities and activities. CSA N286 provides overall direction to management to develop and implement sound management practices and controls, while the other CSA Group nuclear Standards provide technical requirements and guidance that support the management system. These Guidelines work in harmony with CSA N286 and do not duplicate the generic requirements of CSA N286; however, they may provide more specific direction for those requirements.

Scope:

1.1 Facilities
These Guidelines and the CDG are intended to apply to CANDU nuclear power stations in Canada. However, the radionuclides and environmental pathways addressed make these Guidelines applicable to releases from many other nuclear facilities, including research reactors, radioisotope processing facilities, waste processing facilities such as incinerators, and power reactors other than those of CANDU design, subject to the limitations detailed in Clauses 1.2 to 1.8. Application to other types of facilities such as fuel fabrication plants and refineries is limited by the radionuclides considered here (see Clause 4.3). These Guidelines may be adapted to cover part of the needs of such facilities, but additional models or methodologies might be necessary for other parts. However, neither the radionuclides nor the models included in these Guidelines are complete enough to cover releases from sources such as uranium mines and mills, or permanent geologic disposal facilities. In addition, the pathways are incomplete for any facilities where extensive modelling of groundwater pathways is required.

1.2 Release paths
These Guidelines cover releases to the atmosphere and to surface water (both fresh and marine). They do not address releases to groundwater, although transfers from other media to groundwater wells and ponds are considered. Direct gamma irradiation from radioactivity inside the facility is not modelled because it does not involve a release.

1.3 Release duration
The methods specified in these Guidelines are designed for routine, continuous, low-level emissions. They also apply to periodic, short-term releases (see Clause 8.2), provided that
a) the releases are controlled and associated with normal operations;
b) the release rate is roughly the same from event to event;
c) for atmospheric releases, the total release duration exceeds approximately 1000 h in the year; for aquatic releases, at least one or two releases occur in each month of the year; and
d) the releases occur randomly over time.

Where the requirement of Item d) is not met but the releases are known to occur at a particular time of day or year, these Guidelines apply only if the air (water) concentrations are calculated using the meteorological (hydrological) data in effect for that time.

Notes:
1) Where non-random releases are calculated using time-appropriate data, it might be possible to relax the conditions on the release frequencies.
2) Releases that do not meet these conditions can use another model, such as that specified in CSA N288.2 for atmospheric releases.
3) For some facilities, intermittent releases occur predictably as spikes on a continuous base release. Such releases can be considered part of routine emissions and included in the DRL without special treatment if the total activity released in intermittent form is less than approximately 30% of the total release from the facility. The 30% cut-off is considered a small fraction of the overall uncertainty of the DRL estimates.


1.4 Contaminants
These Guidelines apply to the radiation effects of radionuclides. They do not apply to chemicals or to the chemical toxicity of radionuclides.

1.5 Receptors
The model can be used to calculate doses or derive release limits for a representative person having the average characteristics of a group of individuals who, by reason of their location and habits, are likely to receive the highest exposures to a given radionuclide released from a particular source (see Clause 4.2). These Guidelines do not apply to nuclear energy workers (NEWs), or to non-NEWs working at a nuclear facility, who are assumed to be covered by on-site radiation protection programs. The DRLs calculated using the models specified in these Guidelines apply to human receptors only; however, the models can be used to support dose calculations for non-human biota.

1.6 Downwind distance of validity
These Guidelines are not applicable to receptors located close to a source affected by building-induced turbulence because the atmospheric dispersion model does not simulate the cavity that forms in the lee of the building. Because the cavity extends approximately three building heights downwind, these Guidelines apply only beyond this distance. Moreover, the dispersion model should be used with caution beyond an approximate distance of 20 km from the facility because the assumption of steady-state meteorological conditions implicit in the model becomes less valid at greater distances. This is not an issue in practice because the representative person is usually found closer to the facility than 20 km.

1.7 Site specificity
Local parameter values should be used wherever possible when applying models to a specific site. Where local values are not available, the default values given in these Guidelines for the region closest to the site of interest may be used. These regional values represent conditions at the main nuclear sites in Canada (i.e., Pickering/Darlington, Bruce, CRL, G-2, and Point Lepreau) but may be interpreted as default values for the regional areas of southern Ontario, western Ontario, eastern Ontario, Quebec, and the Maritimes, respectively. Some items which make sites unique are: topography (e.g., escarpment, river valley, lake effect), proximity to water bodies, prevalent wind patterns, and surface roughness.

1.8 Level of complexity

1.8.1 Simpler approaches
The models specified in these Guidelines are comprehensive and in some cases include considerable detail. This level of complexity might not be warranted for all assessments. Less complex approaches, involving fewer pathways and/or less detail, might be appropriate under some circumstances. Any pathway that can be shown to not contribute significantly to the total dose may be neglected. In these cases, simpler models such as those described by the IAEA Safety Report Series No. 19 may be used, provided that justification for using a simpler approach is provided.

Note: For example, the following need not be considered:
a) radionuclides that are not released from the site of interest; and
b) pathways related to wells that are not used as a source of water by members of the public near the site.


1.8.2 Default transfer parameters
A simplified approach is available for application of these Guidelines without implementation of the models. Annex A lists default transfer parameters for each radionuclide for each pathway in the model, together with the assumptions made in calculating the values. If the assumptions hold for the application in question, these default values may be used to obtain estimates of the DRLs without implementing the model itself, as demonstrated in Annex B. This allows all of the models and parameter values in these Guidelines to be accessed in a simple way. Because conservative assumptions were made in calculating the default parameter values, the DRLs calculated using this approach will be more conservative than those obtained by implementing the model.

The default transfer parameters can also be applied to conduct an initial assessment, combined with a sensitivity analysis, to determine which pathways or radionuclides merit further efforts to reduce model uncertainty through the application of site-specific measurements (see CDG, Appendix J).

1.9 Terminology
In these Guidelines, "should" is used to express a recommendation or that which is advised but not required and "may" is used to express an option or that which is permissible within the limits of the Guidelines. See more

Also Bought By Customers

  • 2180849

    CSA N287.5:20
    Priced From $790.00

  • 2107585

    CSA N288.1:20 (R2025)
    Priced From $1,790.00

  • 1913777

    CSA N292.1-16 (R2021)
    Priced From $890.00

  • 2095672

    CSA N299.4:19
    Priced From $590.00

 

Document History

  1. CSA N288.1:20 (R2025)

    You are currently viewing this product 👀 currently
    viewing

    March 2020
    Guidelines for modelling radionuclide environmental transport, fate, and exposure associated with the normal operation of nuclear facilities, Includes Errata (2020), Errata (2022) and Update No. 1 (2024)

    • Most Recent  Most Recent
  2. CSA N288.1-14 (R2019)

    March 2014
    Guidelines for Calculating Derived Release Limits for Radioactive Material in Airborne and Liquid Effluents for Normal Operation of Nuclear Facilities, Includes Update No. 1 (2017), Update No. 2 (2017), and Update No. 3 (2018)

    • Historical Version
  3. CSA N288.1-08 (R2013)

    September 2008
    Guidelines for Calculating Derived Release Limits for Radioactive Material in Airborne and Liquid Effluents for Normal Operation of Nuclear Facilities, Includes Update No. 1 (2011)

    • Historical Version
  4. CAN/CSA N288.1-M87 (R2003)

    September 2000
    Guidelines for Calculating Derived Release Limits for Radioactive Material in Airborne and Liquid Effluents for Normal Operation of Nuclear Facilities

    • Historical Version

Browse related products from CSA Group

  • CSA Group > Energy > Nuclear

Order Options

Delivery Options
Price: $1,790.00
Available for Immediate Download

Product Details

Edition:

4th

Published:

03/01/2020

ISBN(s):

9781488325793

Number of Pages:

478

File Size:

1 file

Product Code(s):

2427651, 2427642, 2427651

Note:

This product is restricted and cannot be purchased in the following countries Russia, Ukraine, Belarus
✕

Document Delivery Options

Secure PDF
Also known as an SPDF enforces publisher restrictions around file sharing, printing, and downloading. For more details on these restrictions refer to: Help Center.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/csa-n288-1-20-r2025?product_id=2107585
Referrer: Direct Navigation
IP: 216.73.216.167
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463798633
Order #: None
Cookies: YES
×