accuris store logo
  • Browse all
  • 3A
  • 9000
  • A3
  • A4A
  • AA
  • AAMI
  • AASHTO
  • AATCC
  • ABCB
  • ABMA
  • ABMA-BOILER
  • ACC
  • ACGIH
  • ACI
  • ADA
  • ADS
  • AEIC
  • AENOR
  • AES
  • AFCEN
  • AGA
  • AGMA
  • AHAM
  • AHP
  • AHRI
  • AIA
  • AIAA
  • AICHE
  • AIHA
  • AIIM
  • AISC
  • ALI
  • ALPEMA
  • AMCA
  • ANS
  • ANSI
  • ANSI/ANSLG
  • ANSI/NEMA
  • ANSI/TCNA
  • ANSI/UAMA
  • API
  • APWA
  • AREMA
  • ARINC
  • ARMY
  • AS
  • ASA
  • ASABE
  • ASCE
  • ASD-STAN prEN
  • ASHE
  • ASHRAE
  • ASIS
  • ASM
  • ASME
  • ASNT
  • ASQ
  • ASSE (Plumbing)
  • ASSP
  • ASTM
  • ATIS
  • AVIXA
  • AWC
  • AWI
  • AWPA
  • AWS
  • AWWA
  • B11
  • BHMA
  • BICSI
  • BIFMA
  • BioWorld
  • BMI
  • BS
  • CAN/CGSB
  • CAN/ULC
  • CEI
  • CFR
  • CGA
  • CGSB
  • CIE
  • CII
  • CISPR
  • CLSI
  • CMAA
  • CRANE
  • CRSI
  • CSA
  • CTA
  • CTI
  • DID
  • DIN
  • DNV
  • DOD
  • DOXPUB
  • DVS
  • ECIA
  • EEC
  • EEMUA
  • ESD
  • ETSI
  • FCI
  • FED
  • FM Approvals
  • FORD
  • FRPI
  • GMW
  • GPA
  • HEI
  • HFES
  • HI
  • HIR
  • HPS
  • I3A
  • IADC
  • IAPMO
  • IATA
  • ICAO
  • ICC
  • ICEA
  • ICML
  • IEC
  • IEEE
  • IEEE/UL
  • IES
  • IEST
  • IFI
  • IICRC
  • INCITS
  • INTERN
  • IPC
  • ISA
  • ISEA
  • ISO
  • ISO/IEC/IEEE
  • ISPE
  • ISTA
  • ISUZU
  • JEDEC
  • JIS
  • LIA
  • MBMA
  • MCGRAW-HILL
  • MIL
  • MPIF
  • MSS
  • NAAMM
  • NACE
  • NADCA
  • NAS
  • NASA
  • NBBI
  • NCSL
  • NECA
  • NEMA
  • NETA
  • NFPA (Fire)
  • NFPA (Fluid)
  • NFSI
  • NG
  • NGA
  • NISO
  • NORSOK
  • NRC
  • NSC
  • NSF
  • NZS
  • OPEI
  • PCI
  • PDA
  • PEI
  • PIA
  • PIP
  • PPI
  • RTCA
  • SAE
  • SAIA
  • SCTE
  • SDI
  • SES
  • SIA
  • SJI
  • SMACNA
  • SME
  • SMPTE
  • SN EN
  • SPC
  • SPI
  • SSPC
  • STI/SPFA
  • TAPPI
  • TCIA
  • TEMA
  • THHILL
  • TIA
  • TMS
  • UL
  • ULC
  • UOP
  • WILEY
  • WRC
  • X9
Publishers
Need Help?
Log in
Create Account
Cart

Your shopping cart is empty.

Log in or create account

  1. Home
  2. IEC 61847 Ed. 2.0 b:2025

IEC 61847 Ed. 2.0 b:2025 ✓ Most Recent

2939287  Preview

Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics

standard by International Electrotechnical Commission , 05/01/2025

Track This
👥 Multi-User PDF
✕

Document Set

This document is a set or collection of related documents
✕

Complete Document

The standards and other regulatory documents that Accuris offers are often updated after publication. These updates include errata (known issues to be addressed in the next version), corrigenda (errors or mistakes identified after publication), or amendments (additional information not included in the original document).

When you purchase a document from the Accuris store, you may select whether to buy only the base document or a complete document package that includes all errata, corrigenda, and amendments available for that document at the time of purchase. It does not grant access to errata, corrigenda, or amendments that may be published after the purchase date.
✕

Multi-User PDF

A Multi-User PDF allows you to purchase a finite set of single user licenses for a specific document. The number of user licenses available for purchase varies by document, please see the store listing for more specific information.
✕

Redline

When you purchase a Redline edition of a standard, you will get the current edition of that standard, plus the Redline version, which will show changes between the new edition and the previous edition.
✕

Member Price

Member pricing is available for this product.

Full Description

This document specifies:
– the essential non-thermal output characteristics of ultrasonic surgical units;
NOTE 1 One of the parameters of interest is output acoustic power. This document primarily addresses the low-frequency (under 120 kHz) component of the total delivered energy. The high frequency component, which relates to cavitation developed at the tip, is discussed in Clause A.4.
– methods of measurement of these output characteristics;
– those characteristics to be declared by the manufacturers of such equipment.
NOTE 2 In the interest of clarity, a straight tubular shape is used in the basic description of the parameters and measurements to be made. Guidance is provided to the user of this document to adapt the basic methodology described to more complex designs as required. It is recognized that complex designs and vibration patterns are design features of many surgical systems, and therefore it is important that output characteristics be declared for those conditions.
This document is applicable to equipment which meets the criteria of a), b) and c) below:
a) ultrasonic surgical systems operating in the frequency range 20 kHz to 120 kHz; and
b) ultrasonic surgical systems whose use is the fragmentation, emulsification, debridement, or cutting of human tissue, whether or not those effects are delivered in conjunction with tissue removal or coagulation; and
c) ultrasonic surgical systems in which an acoustic wave is conducted by means of a specifically designed wave guide to deliver energy to the surgical site.
NOTE 3 Examples of these types of systems are surgical aspirators, phacoemulsifiers, intracorporeal lithotripters, end-cutting systems, ultrasonic liposuction systems, etc.
NOTE 4 The upper frequency limit has been set to accommodate more recently developed systems operating at higher frequencies than IEC 61847:1998. The techniques of this document are also useful for systems operating at higher frequencies that use the same mechanisms of action.
This document is not applicable to:
– lithotripsy equipment which uses extracorporeally induced pressure pulses, focused through liquid conducting media and the soft tissues of the body;
– surgical systems used as part of the therapeutic process (hyperthermia systems);
– surgical systems whose mechanism of action is through frictional heat generated by tissue in contact with the wave guide, e.g. clamp coagulators or clamping vibrational cutters;
– surgical systems whose mechanism of action is through focused ultrasound for either thermal degradation (high intensity focused ultrasound – HIFU or HITU) or cavitation erosion (Histotripsy) of tissue remote from the ultrasound transducer;
– surgical systems whose mechanism of action is through erosion of hard tissues in contact with the applicator tip, e.g. bone cutting or drilling.
NOTE 5 Limited declaration requirements for surgical systems whose mechanism of action is through erosion of hard tissues in contact with the applicator tip are listed in Clause 7.

See more

Also Bought By Customers

  • 1876283

    IEC 60601-2-36 Ed. 2.0 b:2014
    Medical electrical equipment - Part 2-36: Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy
    Priced From $190.00

    IEC 60601-2-36 Ed. 2.0 b:2014: Medical electrical equipment - Part 2-36: Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy

  • 2939287

    IEC 61847 Ed. 2.0 b:2025
    Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics
    Priced From $322.00

    IEC 61847 Ed. 2.0 b:2025: Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics

  • 2072680

    IEC/TR 61289 Ed. 2.0 en:2019
    High frequency surgical equipment and high frequency surgical accessories - Operation and maintenance
    Priced From $234.00

    IEC/TR 61289 Ed. 2.0 en:2019: High frequency surgical equipment and high frequency surgical accessories - Operation and maintenance

  • 2899017

    IEC/TS 60601-4-2 Ed. 1.0 en:2024
    Medical electrical equipment – Part 4-2: Guidance and interpretation – Electromagnetic immunity: performance of medical electrical equipment and medical electrical systems
    Priced From $412.00

    IEC/TS 60601-4-2 Ed. 1.0 en:2024: Medical electrical equipment – Part 4-2: Guidance and interpretation – Electromagnetic immunity: performance of medical electrical equipment and medical electrical systems

 

Document History

  1. IEC 61847 Ed. 2.0 b:2025

    You are currently viewing this product 👀 currently
    viewing

    May 2025
    Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics

    • Most Recent  Most Recent
  2. IEC 61847 Ed. 1.0 en:1998

    January 1998
    Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics

    • Historical Version

Browse related products from International Electrotechnical Commission

  • International Electrotechnical Commission > By ICS Code > 11: Health care technology > 11.040: Medical equipment > 11.040.01: Medical equipment in general
  • International Electrotechnical Commission > By ICS Code > 17: Metrology and measurement. Physical phenomena > 17.140: Acoustics and acoustic measurements > 17.140.50: Electroacoustics
  • International Electrotechnical Commission > By Technical Committee > TC 87: Ultrasonics

Order Options

Delivery Options
Price: $322.00
Available for Immediate Download

Product Details

Edition:

2.0

Published:

05/01/2025

ISBN(s):

9782832704424

Number of Pages:

31

File Size:

1 file

Note:

This product is restricted and cannot be purchased in the following countries Ukraine, Russia, Belarus
✕

Document Delivery Options

PDF
A Portable Document Format which is electronic and downloadable. All PDF's can be downloaded from your My Downloads page in your Accuris Store account. Refer to Help Center for more details.
Printed Edition
A vast majority of our standards are available in printed format. Sometimes these are bound like a book, sometimes loose pages that you can put in a binder.
Printed Edition + PDF
A combination of a Hard Copy product that is mailed and an electronic product such as a PDF or SPDF (Secure PDF). Refer to Help Center for more details.
✕

What is a Secured PDF?

Secured PDFs are equipped with Digital Rights Management (DRM) software, by request of the Publisher to protect the copyright of the Publication, preventing unauthorized duplication and distribution.

What does this mean?

To view the PDF, a DRM tool, FileOpen must be installed. FileOpen is a free plugin which is compatible with Adobe Acrobat Reader DC and Pro DC, as well as other PDF Readers noted on the FileOpen website.

What can you do with a Secured PDF?

  • Print (except for IADC, ICML)
  • Search
  • Highlight
  • Bookmark

Restrictions:

  • Some Publishers do not allow printing.
  • Most Publishers do not permit copy and pasting from the PDF.
  • Sharing, Duplicating and Distribution prohibited.
  • For further information on restrictions, please click here.

PRODUCTS & SERVICES

  1. BPVC 2025
  2. BPVC Previous Editions
  3. Engineering Workbench
  4. Track It

CUSTOMER CARE

  1. Help Center
  2. Glossary
  3. Search Tips

CONNECT WITH US

  1. Contact Us

COMPANY INFORMATION

  1. About Accuris
  2. Press
  • © Copyright 2026 ACCURIS
  • Privacy Policy
  • System Information
Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; +claudebot@anthropic.com)
Store Name: css
Page: /standards/iec-61847-ed-2-0-b-2025?product_id=2939287
Referrer: Direct Navigation
IP: 216.73.217.20
Language: en
Customer #: Not Logged In
Member?: NO
Cart #: 1463894749
Order #: None
Cookies: NO
×